LiftMaster CAPXS Installation Manual - English French Spanish - Page 16

Gate Access (wired), Request To Exit, Primary Relay, Auxiliary Relay, Supervised, Gate Status

Page 16 highlights

INTRODUCTION ACCOUNT SETUP POWER NETWORK/MOUNTING ACCESS CONTROL Gate Access (Wired) Disconnect power BEFORE making electrical connections. Below is an example of a wiring setup for gate access. WIEGAND KEYPAD READER OR NOTE: For KPR2000 keypad wire the pink and black (ground) wires together. SUPERVISED (GATE STATUS) (Not applicable for wireless gate operator connections) GATE OPERATOR (connect to Aux Closed Limit switch - refer to gate operator manual) EOL (End of Line) Resistor (1k ohm) REQUEST TO EXIT EXTERNAL FREE EXIT PUSH LOOP DETECTOR BUTTON OR PRIMARY RELAY GATE OPERATOR EXIT COMMON 12 VDC POWER SUPPLY POSTAL LOCK** POSTAL LOCK NORMALLY OPEN COMMON GROUND DATA 0 DATA 1 REQUEST TO EXIT GROUND SUP NORMALLY OPEN COMMON NORMALLY OPEN COMMON NORMALLY CLOSED GROUND POWER POWER *AUXILIARY RELAY MAGLOCK Use 18-22 AWG For AC Power: Install a Siemens S10K30MOV (Metal Oxide Varistor) or equivalent NORMALLY CLOSED For DC Power: Install a 1N4005 diode or equivalent - COMMON + Power for Maglock (Not Provided) DO NOT use the power supply for the controller AUXILIARY RELAY Low Voltage Power Supply Isolation Relay LIGHT LOAD LINE NEUTRAL NOTE: DO NOT connect high voltage power to OR the CAPXS unit. ALARM BYPASS ETHERNET CONNECTION DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE UNLESS PERMITTED BY THE LOCAL AUTHORITY HAVING JURISDICTION. Doing so may cause interference with the operation of panic hardware. COMMON NORMALLY OPEN * NOTE: MAGLOCK and ALARM BYPASS not evaluated by UL. ** NOTE: For more information on how to wire in a postal lock, refer to the manual for accessory: CAPXSTKPL. 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

16
INTRODUCTION
ACCOUNT SETUP
NETWORK/MOUNTING
POWER
ACCESS CONTROL
Gate Access (Wired)
Disconnect power BEFORE making electrical connections.
Below is an example of a wiring setup for gate access.
GROUND
POWER
GROUND
DATA 0
DATA 1
POWER
ETHERNET CONNECTION
POSTAL LOCK
POSTAL LOCK**
NOTE:
For KPR2000 keypad
wire the pink and black (ground)
wires together.
READER
KEYPAD
WIEGAND
+
NORMALLY OPEN
COMMON
NORMALLY OPEN
NORMALLY CLOSED
COMMON
REQUEST TO EXIT
GROUND
NORMALLY OPEN
COMMON
PUSH
BUTTON
MAGLOCK
12 VDC POWER SUPPLY
OR
EXTERNAL FREE EXIT
LOOP DETECTOR
For DC Power:
Install a 1N4005
diode or equivalent
Use 18-22 AWG
Power for Maglock
(Not Provided)
DO NOT
use the power
supply for the controller
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) or
equivalent
NORMALLY CLOSED
COMMON
OR
REQUEST TO EXIT
PRIMARY RELAY
*AUXILIARY RELAY
GATE OPERATOR
COMMON
EXIT
ALARM BYPASS
LIGHT
NORMALLY OPEN
COMMON
LOAD
LINE
AUXILIARY RELAY
OR
NEUTRAL
** NOTE:
For more information on how
to wire in a postal lock, refer to the
manual for accessory: CAPXSTKPL.
* NOTE:
MAGLOCK and ALARM BYPASS
not evaluated by UL.
NOTE:
DO NOT
connect high
voltage power to
the CAPXS unit.
Isolation
Relay
Low
Voltage
Power
Supply
GATE OPERATOR
(connect to Aux Closed Limit
switch - refer to gate operator
manual)
SUPERVISED
(GATE STATUS)
(Not applicable for wireless
gate operator connections)
EOL (End of Line)
Resistor
(1k ohm)
SUP
DO NOT INSTALL THE
SYSTEM IN THE FAIL
SECURE MODE UNLESS
PERMITTED BY THE LOCAL
AUTHORITY HAVING
JURISDICTION. Doing so may
cause interference with the
operation of panic hardware.