Panasonic AG-HPX370 Studio System 300 Installation Guide - Page 32

Clear-Com Intercom Connection to AG-BS300

Page 32 highlights

Panasonic Solutions Company Section 5 - Intercom Connection Clear-Com Intercom Connection to AG-BS300 AG-BS300 A Clear-Com IF4W-4 Interface is required to connect to the AG-BS300. 1. Set INCOM switch on AG-BS300 to 4W 2. Turn down all volume levels before powering on. 3. Connect Pin 1 on AG-BS300 to Pin 4 on IF4W-4 4. Connect Pin 3 on AG-BS300 to Pin 1 on IF4W-4 5. Connect Pin 6 on AG-BS300 to Pin 5 on IF4W-4 6. Connect Pin 7 on AG-BS300 to Pin 2 on IF4W-4 RECV 1 IF4W-4 Terminal RECV 2 Block INT Rear Panel GRD 3 XMIT 4 XMIT 5 IMPORTANT NOTE: If not connecting to an RTS or Clear-Com System, 200ohm Termination must be installed between Pins 7 and 8 on the AG-BS300 INCOM/TALLY Connection. AG-BS300 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50

Section 5 – Intercom Connection
Clear-Com Intercom Connection to AG-BS300
Panasonic Solutions Company
IF4W-4
Terminal
Block
Rear Panel
1
2
3
4
5
RECV
RECV
XMIT
XMIT
INT
GRD
32
A Clear-Com IF4W-4 Interface is required to connect to the AG-BS300.
AG-BS300
1. Set INCOM switch on AG-BS300 to 4W
2. Turn down all volume levels before powering on.
3. Connect Pin 1 on AG-BS300 to Pin 4 on IF4W-4
4. Connect Pin 3 on AG-BS300 to Pin 1 on IF4W-4
5. Connect Pin 6 on AG-BS300 to Pin 5 on IF4W-4
6. Connect Pin 7 on AG-BS300 to Pin 2 on IF4W-4
AG-BS300
IMPORTANT NOTE: If not connecting to an RTS or Clear-Com System, 200ohm Termination