Panasonic AW-HS50 Basic Operating Instructions - Page 33

Supplied AC adapter, AC 100 V to 240 V, 1.3 A, 47 Hz to 63 Hz

Page 33 highlights

4. Specifications Control I/O Other LAN (RJ-45) 10BASE-T/100BASE-TX (For IP control) Connecting cable: LAN cable (category 5 or above), max. 100 m [328 ft.], STP (Shielded Twisted Pair) cable recommended  When connecting to a hub (switching hub), use a straight cable. Use a crossover cable when connecting the unit and another device on a 1:1 basis without going through a hub. TALLY/GPI (D-sub 15-pin, female, inch thread) INPUT : 5 inputs, photocoupler sensing OUTPUT : 7 outputs, open collector output (negative logic) SERVICE switch [SV/NM] (for maintenance purposes) Normally, this switch is used as the "NM" position. Ambient operating temperature Humidity Power requirements Current consumption Dimensions (W  H  D) Mass 0 °C to 40 °C (32 °F to 104 °F) 10 % to 90 % (no condensation) DC 12 V 10 % (AC adapter provided) 2.0 A (DC 12 V) 210  67  177 mm (8-1/4˝  2-5/8˝  6-15/16˝) [excluding protrusions] 1.4 kg (3.08 lbs.) Supplied AC adapter Rated input: AC 100 V to 240 V, 1.3 A, 47 Hz to 63 Hz Rated output: DC 12 V, 3.5 A, 42 W The provided power cable is for 125 V AC or less. Use it within AC 100 V to 120 V.  The AC adapter and power cable provided must be used without fail. Mass and dimensions shown are approximate. Specifications are subject to change without notice. 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

33
Control I/O
LAN (RJ-45)
10BASE-T/100BASE-TX
(For IP control)
Connecting cable:
LAN cable (category 5 or above),
max. 100 m [328 ft.], STP (Shielded Twisted Pair)
cable recommended
When connecting to a hub (switching hub), use a
straight cable.
Use a crossover cable when connecting the unit
and another device on a 1:1 basis without going
through a hub.
TALLY/GPI
(D-sub 15-pin, female,
inch thread)
INPUT
: 5 inputs, photocoupler sensing
OUTPUT :
7 outputs, open collector output
(negative logic)
Other
SERVICE switch [SV/NM] (for maintenance purposes)
Normally, this switch is used as the “NM” position.
Ambient operating
temperature
0 °C to 40 °C (32 °F to 104 °F)
Humidity
10 % to 90 % (no condensation)
Power requirements
DC 12 V
10 % (AC adapter provided)
Current consumption
2.0 A (DC 12 V)
Dimensions
(W
H
D)
210
67
177 mm (8-1/4˝
2-5/8˝
6-15/16˝)
[excluding protrusions]
Mass
1.4 kg (3.08 lbs.)
Supplied AC adapter
Rated input:
AC 100 V to 240 V, 1.3 A, 47 Hz to 63 Hz
Rated output:
DC 12 V, 3.5 A, 42 W
The provided power cable is for 125 V AC or less.
Use it within AC 100 V to 120 V.
The AC adapter and power cable provided must be used without fail.
Mass and dimensions shown are approximate.
Specifications are subject to change without notice.
4. Specifications