Samsung NX58R5601SS/AA Installation Guide - Page 17
Installation requirements
View all Samsung NX58R5601SS/AA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Installation requirements Installation requirements Location requirements Clearances and dimensions NOTE For OTR over Gas Stove, please follow local GAS CODE. BEFORE YOU BEGIN to install this appliance, refer to the following information, dimensions, and clearances. Do not locate the range where it may be subject to strong drafts. Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for safe use of the range. The location of the electrical outlet and gas piping may be adjusted to meet the following dimensions and clearances. For installation in Canada, a free-standing range is not to be installed closer than 4.7" (12 cm) from any adjacent surface. CAUTION This range has been designed to comply with the maximum allowable wood cabinet temperature of 194 °F (90 °C). Make sure the wall covering, countertops, and cabinets around the range can withstand the heat (up to 194 °F [90 °C]) generated by the range. If not, discoloration, delamination, or melting may occur. Side Clearance Above Cooking Surface to 4" Wall (10.2 cm) Minimum from top of cooktop to cabinets 30" (76.2 cm) 30" 6" 18" (76.2 cm) (15.2 cm) (45.7 cm) 13" (33 cm) Overhead Cabinet Depth 36" (91.4 cm) 24" (61 cm) Lower Cabinet Depth 0" (0 cm) Clearance Below Cooking Top and at Rear and Sides of Range 0" (0 cm) Minimum dimensions WARNING If overhead cabinets are provided, a range hood should also be provided that projects horizontally a minimum of 5" (12.7 cm) beyond the front of the cabinets. This will dissipate any heat buildup in the overhead cabinets to prevent death, personal injury, and/or fire hazard. The ventilating hood must be constructed of sheet metal not less then 0.0122" thick. Install above the cooktop with a clearance of not less than 1/4" between the hood and the underside of the combustible material or metal cabinet. The hood must be at least as wide as the appliance and centered over the appliance. Clearance between the cooking surface and the ventilation hood surface must never be less than 24". Exception: Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installations packed with that appliance. • 30" (101.6 cm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or If no 30" (101.6 cm) minimum clearance, 24" (61 cm) minimum when the bottom of the wood or metal cabinet is protected by not less than 0.25" (0.64 cm) flame-retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" (0.038 cm) stainless steel, 0.024" (0.061 cm) aluminum, or 0.020" (0.051 cm) copper. • 18" (45.7 cm) minimum between the countertop and the adjacent cabinet bottom. English 17