Samsung NX58R5601SS/AA Installation Guide - Page 7

Grounding Instructions, Installation Warnings, Electrical Warnings - gas range

Page 7 highlights

Safety instructions Safety instructions ELECTRICAL WARNINGS Comply with the following electrical instructions and requirements to avoid death, personal injury from electric shock, and/or property damage from fire: 1. Plug into a grounded 3-prong outlet. 2. DO NOT remove ground prong. 3. DO NOT use an adapter. 4. NEVER use an extension cord. Use a dedicated 120-volt, 60-Hz, 20-amp, AC, fused electrical circuit for this appliance. A time-delay fuse or circuit breaker is recommended. DO NOT plug more than one appliance in this circuit. The range is supplied with a 3-prong grounded plug. This cord MUST be plugged into a mating, grounded 3-prong outlet that meets all local codes and ordinances. If you are unsure your electrical outlet is properly grounded, have it checked by a licensed electrician. If codes permit the use of a separate ground wire, it is recommended that a qualified electrician determine the proper path for this ground wire. Electrical service to the range must conform to local codes. Barring local codes, it should meet the latest ANSI/NFPA No. 70 - Latest Revision (for the U.S.) or the Canadian Electrical Code CSA C22.1 - Latest Revisions. It is the personal responsibility of the appliance owner to provide the correct electrical service for this appliance. NEVER connect ground wire to plastic plumbing lines, gas lines, or hot water pipes. DO NOT modify the plug provided with the appliance. DO NOT a have fuse in a neutral or ground circuit. GROUNDING INSTRUCTIONS Grounding a range with a cord connection: This appliance must be Earth grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical shock by providing a path for the electric current. This appliance is equipped with a cord having a grounding plug. The plug must be firmly plugged into an outlet that is properly installed and grounded in accordance with the local codes and ordinances. WARNING Improper connection of the grounding plug can result in a risk of electric shock. Check with a qualified electrician if you have any doubt the appliance is properly grounded. NEVER modify the plug provided with the appliance. If it does not fit the existing outlet, have a qualified electrician install a proper outlet. INSTALLATION WARNINGS Have your range installed and properly grounded by a qualified installer, in accordance with the grounding instructions on page 20. Any adjustment and service should be performed only by qualified gas range installers or service technicians. Be sure your range is correctly installed and adjusted by a qualified service technician or installer for the type of gas (natural or LP) that is to be used. To utilize LP fuel source, the 5 surface burner orifices, 2 oven orifices must be exchanged with the provided LP orifice set, and the GPR adapter must be reversed. English 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

English 7
Safety instructions
Safety instructions
GROUNDING INSTRUCTIONS
Grounding a range with a cord connection:
This appliance must be Earth grounded. In the event of a malfunction or
breakdown, grounding will reduce the risk of electrical shock by providing
a path for the electric current. This appliance is equipped with a cord having
a grounding plug. The plug must be firmly plugged into an outlet that is
properly installed and grounded in accordance with the local codes and
ordinances.
WARNING
Improper connection of the grounding plug can result in a risk of electric shock.
Check with a qualified electrician if you have any doubt the appliance is properly
grounded.
NEVER modify the plug provided with the appliance. If it does not fit the
existing outlet, have a qualified electrician install a proper outlet.
INSTALLATION WARNINGS
Have your range installed and properly grounded by a qualified installer, in
accordance with the grounding instructions on page
20
. Any adjustment and
service should be performed only by qualified gas range installers or service
technicians.
Be sure your range is correctly installed and adjusted by a qualified service
technician or installer for the type of gas (natural or LP) that is to be used.
To utilize LP fuel source, the 5 surface burner orifices, 2 oven orifices must
be exchanged with the provided LP orifice set, and the GPR adapter must be
reversed.
ELECTRICAL WARNINGS
Comply with the following electrical instructions and requirements to avoid death,
personal injury from electric shock, and/or property damage from fire:
1.
Plug into a grounded 3-prong outlet.
2.
DO NOT remove ground prong.
3.
DO NOT use an adapter.
4.
NEVER use an extension cord.
Use a dedicated 120-volt, 60-Hz, 20-amp, AC, fused electrical circuit for this
appliance. A time-delay fuse or circuit breaker is recommended. DO NOT plug
more than one appliance in this circuit.
The range is supplied with a 3-prong grounded plug. This cord MUST be
plugged into a mating, grounded 3-prong outlet that meets all local codes
and ordinances. If you are unsure your electrical outlet is properly grounded,
have it checked by a licensed electrician.
If codes permit the use of a separate ground wire, it is recommended that a
qualified electrician determine the proper path for this ground wire.
Electrical service to the range must conform to local codes. Barring local
codes, it should meet the latest ANSI/NFPA No. 70 – Latest Revision (for the
U.S.) or the Canadian Electrical Code CSA C22.1 – Latest Revisions.
It is the personal responsibility of the appliance owner to provide the correct
electrical service for this appliance.
NEVER connect ground wire to plastic plumbing lines, gas lines, or hot water
pipes.
DO NOT modify the plug provided with the appliance.
DO NOT a have fuse in a neutral or ground circuit.