Samsung NX58R5601SS/AA Installation Guide - Page 30
To adjust flame low setting, Simmer Set
View all Samsung NX58R5601SS/AA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
Installation instructions Memo To adjust flame low setting Identify which burner is exhibiting too high or too low of simmer rate via manifold panel graphics. 1. Rotate a knob to "LO" position and remove the knob from the valve shaft while the flame is lit. Simmer Set Screw 2. Carefully push the screw driver into the C chanel of the valve, until it his the simmer set screw. Make sure the screwdriver flathead is seated into the set screw groove. Installation instructions 3. Rotate valve set screw clockwise to decrease "LO" setting flame output, or rotate set screw counter clockwise to increase "LO" setting flame output. WARNING 1. Do not completely remove the valve set screw from the valve stem. The valve set screw is an integral part of the gas valve assembly. Removing the valve set screw will cause gas to leak. 2. After adjusting the valve set screw, inspect the assembly for gas leaks. 30 English