Sanyo WXU700 Instruction Manual, PLC-WXU700A - Page 65

Cleaning the Filters, Resetting the Filter Counter, Filter counter

Page 65 highlights

Maintenance and Cleaning Cleaning the Filters Filter prevents dust from accumulating on the optical elements inside the projector. Should the filters become clogged with dust particles, it will reduce cooling fans' effectiveness and may result in internal heat buildup and adversely affect the life of the projector. If a Filter warning icon appears on the screen, clean the filters immediately. Clean the filters by following the steps below. 1 Turn off the projector, and unplug the AC power cord from the AC outlet. 2 Turn the projector over and remove the filters by pulling the latches upward. 3 Gently clean the filters by using a brush or rinse it softly. 4 When rinsing the filters, dry they well. Replace the filters properly. Make sure that the filters are fully inserted to the projector. CAUTION Do not operate the projector with the filters removed. Dust may accumulate on the optical elements degrading picture quality. Do not put anything into the air vents. Doing so may result in malfunction of the projector. Filters Pull up and remove. RECOMMENDATION We recommend avoiding dusty/smoky environments when you operate the projector. Usage in these environments may cause poor image quality. When using the projector under dusty or smoky conditions, dust may accumulate on a lens, LCD panels, or optical elements inside the projector degrading the quality of a projected image. When the symptoms above are noticed, contact your authorized dealer or service station for proper Filter counter cleaning. H Resetting the Filter Counter Be sure to reset the Filter counter after cleaning or replacing the filters. 1 Press the MENU button to display the On-Screen Menu. Use the Point ▲▼ buttons to select Setting and then press the Point ► or the SELECT button. 2 Use the Point ▲▼ buttons to select Filter counter and then press the SELECT button. Use the Point ▲▼ buttons to select Filter counter reset and then press the SELECT button. Filter counter Reset? appears. Select Yes to continue. 3 Another confirmation dialog box appears, select Yes to reset the Filter counter. Filter counter Reset? appears. Select Yes, then another confirmation box appears. Select Yes again to reset the Filter counter. 65

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85

65
Maintenance and Cleaning
Filter prevents dust from accumulating on the optical elements inside the projector. Should the filters become
clogged with dust particles, it will reduce cooling fans’ effectiveness and may result in internal heat buildup
and adversely affect the life of the projector. If a Filter warning icon appears on the screen, clean the filters
immediately. Clean the filters by following the steps below.
CAUTION
Do not operate the projector with the filters
removed. Dust may accumulate on the optical
elements degrading picture quality.
Do not put anything into the air vents. Doing so
may result in malfunction of the projector.
RECOMMENDATION
We recommend avoiding dusty/smoky environments
when you operate the projector° Usage in these
environments may cause poor image quality°
When using the projector under dusty or smoky conditions,
dust may accumulate on a lens, LCD panels, or optical
elements inside the projector degrading the quality of a
projected image. When the symptoms above are noticed,
contact your authorized dealer or service station for proper
cleaning.
Be sure to reset the Filter counter after cleaning or replacing
the filters.
Press the MENU button to display the On-Screen
Menu. Use the Point
▲▼
buttons to select
Setting
and
then press the Point
or the
SELECT
button.
Use the Point
▲▼
buttons to select
Filter counter
and then press the SELECT button. Use the Point
▲▼
buttons to select
Filter counter reset
and then press
the SELECT button.
Filter counter Reset?
appears.
Select
Yes
to continue.
1
±
Resetting the Filter Counter
Filter counter
Filter counter Reset?
appears.
Select
Yes
, then another
confirmation box appears.
Select
Yes
again to reset
the Filter counter.
Another confirmation dialog box appears, select
Yes
to
reset the Filter counter.
3
Cleaning the Filters
H
Turn off the projector, and unplug the AC power cord
from the AC outlet.
Turn the projector over and remove the filters by pulling
the latches upward.
1
±
Gently clean the filters by using a brush or rinse it
softly.
3
When rinsing the filters, dry they well. Replace the
filters properly. Make sure that the filters are fully
inserted to the projector.
4
Filters
Pull up and remove.