Seagate ST15150N Product Manual - Page 38

lfpm and inlet air temperature to the drive was 30°C 86°F, plus a 5°C

Page 38 highlights

28 ST15150N/ND/W/WD/WC/DC Product Manual, Rev. D Air-flow cooling ST15150WC drives single-ended wide (SCA) Card JYHX JYHX JYHX JYHX JYHX HDA housing Component Polar Writer CSAW Pike Driver Reference 1 2 3 4 5 Figure 13 MTBF 800k hours case temperature (°C) 48 64 47 52 60 The air-flow pattern with which the temperature guidelines above were generated is shown in Figure 6. Local average air velocities were 0.61 msec (120 lfpm) and inlet air temperature to the drive was 30°C (86°F), plus a 5°C temperature rise in the test enclosure (35°C ambient local to the drive). The maximum allowable HDA case temperature is 60°C. 2 1 5 3 4 Figure 11. JYHX temperature measurement locations

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

28
ST15150N/ND/W/WD/WC/DC Product Manual, Rev. D
Air-flow cooling
ST15150WC drives
single-ended wide (SCA)
MTBF
800k hours
Card
Component
Reference
case temperature (°C)
JYHX
Polar
1
48
JYHX
Writer
2
64
JYHX
CSAW
3
47
JYHX
Pike
4
52
JYHX
Driver
5
60
HDA housing
Figure 13
The air-flow pattern with which the temperature guidelines above were
generated is shown in Figure 6. Local average air velocities were 0.61 msec
(120 lfpm) and inlet air temperature to the drive was 30°C (86°F), plus a 5°C
temperature rise in the test enclosure (35°C ambient
local to the drive).
The maximum allowable HDA case temperature is 60°C.
2
4
5
3
1
Figure 11. JYHX temperature measurement