Seagate ST15150N Product Manual - Page 80

Connector requirements

Page 80 highlights

70 11.7.1.2.3 11.7.2 ST15150N/ND/W/WD/WC/DC Product Manual, Rev. D General cable characteristics In general, cables having the characteristic impedances given in Sections 11.7.1.2.1 and 11.7.1.2.2 are not available; however, impedances that are somewhat lower are satisfactory. A characteristic impedance of 100 ohm +10% is recommended for non-shielded flat or twisted-pair ribbon cable. However, most available cables have a somewhat lower characteristic impedance. To minimize discontinuities and signal reflections, cables of different impedances should not be used in the same bus. Your specific setup may require tradeoffs in shielding effectiveness, cable length, the number of loads, transfer rates, and cost to achieve satisfactory system operation. If shielded and non-shielded cables are mixed within the same SCSI bus, the effect of impedance mismatch must be carefully considered. Proper impedance matching is especially important to maintain adequate margin at fast SCSI transfer rates. Only non-shielded cable connectors are applicable for N and ND drives. A 50-conductor flat cable or 25 twisted-pair cable is used. A minimum conductor size of 28 AWG should be used to minimize noise effects. Suggested nonshielded flat cable part numbers are: Flat cable, 35M-3365-50 Twisted pair, Spectra Twist in flat 455-248-50 Equivalent parts may be used. Connector requirements ST15150N/ND drives The non-shielded cable connector is a 50-conductor connector consisting of two rows of 25 female contacts with adjacent contents 100 mils apart. Recommended mating flat cable connectors part numbers: Closed end 3M-3425-7000 without strain relief, no center key (for cable ends) 3M-3425-7050 with strain relief, no center key Berg-66900-290 with strain relief, with center key Open end (in daisy chain) 3M-3425-6000 without strain relief, no center key 3M-3425-6050 with strain relief, no center key Berg-66900-250 with strain relief, with center key The drive device connector is a non-shielded 50-conductor connector consisting of two rows of 25 male pins with adjacent pins 100 mils apart. The connector is keyed (see Figure 33). Mating panel mount connector 3M-CHE-2050-J01A10-KLE ST15150W/WD drives Recommended mating wide cable connectors part numbers: AMP 786096-7, female 68-pin AMP 786090-7, male 68-pin

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102

70
ST15150N/ND/W/WD/WC/DC Product Manual, Rev. D
11.7.1.2.3
General cable characteristics
In general, cables having the characteristic impedances given in Sections
11.7.1.2.1 and 11.7.1.2.2 are not available; however, impedances that are
somewhat lower are satisfactory. A characteristic impedance of 100 ohm
+
10% is recommended for non-shielded flat or twisted-pair ribbon cable.
However, most available cables have a somewhat lower characteristic
impedance. To minimize discontinuities and signal reflections, cables of
different impedances should not be used in the same bus. Your specific setup
may require tradeoffs in shielding effectiveness, cable length, the number of
loads, transfer rates, and cost to achieve satisfactory system operation. If
shielded and non-shielded cables are mixed within the same SCSI bus, the
effect of impedance mismatch must be carefully considered. Proper imped-
ance matching is especially important to maintain adequate margin at fast
SCSI transfer rates.
Only non-shielded cable connectors are applicable for N and ND drives. A
50-conductor flat cable or 25 twisted-pair cable is used. A minimum conduc-
tor size of 28 AWG should be used to minimize noise effects. Suggested non-
shielded flat cable part numbers are:
Flat cable, 35M-3365-50
Twisted pair, Spectra Twist in flat 455-248-50
Equivalent parts may be used.
11.7.2
Connector requirements
ST15150N/ND drives
The non-shielded cable connector is a 50-conductor connector consisting of
two rows of 25 female contacts with adjacent contents 100 mils apart.
Recommended mating flat cable connectors part numbers:
Closed end
3M-3425-7000 without strain relief, no center key
(for cable ends)
3M-3425-7050 with strain relief, no center key
Berg-66900-290 with strain relief, with center key
Open end
3M-3425-6000 without strain relief, no center key
(in daisy chain)
3M-3425-6050 with strain relief, no center key
Berg-66900-250 with strain relief, with center key
The drive device connector is a non-shielded 50-conductor connector
consisting of two rows of 25 male pins with adjacent pins 100 mils apart. The
connector is keyed (see Figure 33).
Mating panel mount connector 3M-CHE-2050-J01A10-KLE
ST15150W/WD drives
Recommended mating wide cable connectors part numbers:
AMP 786096-7, female 68-pin
AMP 786090-7, male 68-pin