Sharp ER-A450T Programmer Manual - Page 47

Op X/z, X1/z1,x2/z2 Mode

Page 47 highlights

CHAPTER 3. OP X/Z, X1/Z1,X2/Z2 MODE The following categories of reports can be printed by the ECR. OP X/Z reports: These reports are taken by operators in order to report their own sales data. XI/Z1 reports: These reports are taken by the supervisor or manager in order to check and report daily sales totals at that point. X2/Z2 reports: These reports are taken by the owner or manager in order to check and report periodic (weekly or monthly) totals. REPORT NAME GENERAL UPC (All) (Pick up) UPC BY DEPT. UPC ZERO SALES (All) (By DEPT.) DEPT./GROUP IND. GROUP GROUP TOTAL PLU BY RANGE PLU BY DEPT. PLU ZERO SALES (All) (By DEPT.) PLU PRICE CATEGORY TRANSACTION CID ALL CASHIER IND. CASHIER HOURLY (All) (Range) DAILY NET PBLU PBLU BY CASHIER STACKED REPORT DEPT. SALES (Frash-read) CID (Frash-read) DAILY MET SALES (Frash-read) NON-ACCESSED UPC DELETE OF NON-ACCESSED UPC OP X/Z X Z X1/Z1 X1 Z1 (*) At this operation, the non-accessed UPCs data are printed and deleted. To stop the printing reports: The printing of all reports can be stopped by the following operation. Set the mode switch to "MGR" to cancel. Note) When the printing is stopped, the consecutive number or Z counter doesn't return to the original value. For Z reports, Memory is not reset when canceled. *1 X1: Daily X report X2: Periodic X report Z1: Daily Z report Z2: Periodic Z report MGR/Flash-read: These reports are taken by the owner or manager in order to check and display daily sales totals at that point. To print reports, use the following key entry sequence Reading JOB# Resetting @/FOR Range is required CA/AT MODE *1 X2/Z2 JOB# or KEY X2 Z2 *3 00 09 09 01 07 07 10 12 13 20 21 27 27 29 30 31 50 51 60 60 70 80 81 90 DEPTn [@/FOR] [SBTL] 105 105(*) 105(*) DATA FOR READING NOTE --- --- PICK UP *4 DEPT CODE --- DEPT CODE --- GROUP No. --- PLU CODE *2 DEPT CODE --- DEPT CODE PRICE *2 --- --- --- --- --- TIME *2 --- PBLU CODE *2 --- --- *5 --- *5 --- *5 --- --- PICK UP *4 *2 The time interval range and PLU code range can be specified by entering the start and end numbers according to the following procedure. When specifying a single time interval or PLU code, the start number has only to be entered. All XXXXXX Start No. @/FOR XXXXXX End No. *3 When 2 is entered in the third digit of a job code, periodic reports are printed. Example: Daily general report; job code 100 Periodic general report; job code 200

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49

CHAPTER 3. OP X/Z, X1/Z1,X2/Z2 MODE
The following categories of reports can be printed by the ECR.
OP X/Z reports:
These reports are taken by operators in order to
report their own sales data.
XI/Z1 reports:
These reports are taken by the supervisor or man-
ager in order to check and report daily sales totals
at that point.
X2/Z2 reports:
These reports are taken by the owner or manager
in order to check and report periodic (weekly or
monthly) totals.
MGR/Flash-read:
These reports are taken by the owner or manager
in order to check and display daily sales totals at
that point.
To print reports, use the following key entry sequence
MODE
*1
OP X/Z
X1/Z1
X2/Z2
JOB# or KEY
DATA FOR READING
REPORT NAME
X
Z
X1
Z1
X2
Z2
*3
NOTE
GENERAL
00
---
UPC (All)
09
---
(Pick up)
09
PICK UP
*4
UPC BY DEPT.
01
DEPT CODE
UPC ZERO SALES (All)
07
---
(By DEPT.)
07
DEPT CODE
DEPT./GROUP
10
---
IND. GROUP
12
GROUP No.
GROUP TOTAL
13
---
PLU BY RANGE
20
PLU CODE
*2
PLU BY DEPT.
21
DEPT CODE
PLU ZERO SALES (All)
27
---
(By DEPT.)
27
DEPT CODE
PLU PRICE CATEGORY
29
PRICE
*2
TRANSACTION
30
---
CID
31
---
ALL CASHIER
50
---
IND. CASHIER
51
---
HOURLY (All)
60
---
(Range)
60
TIME
*2
DAILY NET
70
---
PBLU
80
PBLU CODE
*2
PBLU BY CASHIER
81
STACKED REPORT
90
---
DEPT. SALES (Frash-read)
DEPTn
---
*5
CID (Frash-read)
[@/FOR]
---
*5
DAILY MET SALES (Frash-read)
[SBTL]
---
*5
NON-ACCESSED UPC
105
---
DELETE OF NON-ACCESSED UPC
105(*)
---
105(*)
PICK UP
*4
(*)
At this operation, the non-accessed UPCs data are printed and
deleted.
To stop the printing reports:
The printing of all reports can be stopped by the following operation.
Set the mode switch to "MGR" to cancel.
Note)
When the printing is stopped, the consecutive number or Z
counter doesn’t return to the original value.
For Z reports, Memory is not reset when canceled.
*1
X1: Daily X report
X2: Periodic X report
Z1: Daily Z report
Z2: Periodic Z report
*2
The time interval range and PLU code range can be specified by
entering the start and end numbers according to the following
procedure. When specifying a single time interval or PLU code,
the start number has only to be entered.
*3
When 2 is entered in the third digit of a job code, periodic reports
are printed.
Example:
Daily general report;
job code 100
Periodic general report;
job code 200
JOB#
@/FOR
CA/AT
Reading
Resetting
Range is required
All
Start No.
End No.
@/FOR
XXXXXX
XXXXXX