Controlling the Monitor with a PC (RS-232C) RS-232C command table How to read the command table Command: Direction: Command field (See page 18.) W When the "Parameter" is set in the parameter field (see page 18), the command functions as described under "Control/Response Contents". R The returned value indicated under "Reply" can be obtained by setting "????", " ?" or "???+" (repeater control) in the parameter field (see page 18). Parameter: Reply: Parameter field (See page 18.) Response (Returned value) *1: "●" indicates a command which can be used in power standby mode regardless of the STANDBY MODE setting. "○" indicates command which can be used in power standby mode when STANDBY MODE is set to STANDARD. (It cannot be used in the power standby mode when LOW POWER is selected.) "-" indicates a command which cannot be used in power standby mode. *2: PN-ZB01 (optional) limitations (A) When PN-ZB01 (optional) is not attached, (B) When PN-ZB01 (optional) is attached. ○ : The command can be used. - : Error (ERR) Power control/Input mode selection Function POWER CONTROL INPUT MODE SELECTION Command Direction POWR W R Parameter 0 1 INPS W 0 1 2 3 4 6 7 8 9 10 R Reply Control/Response contents *2 *1 (A) (B) Switches to standby mode. Returns from standby mode. 0 Standby mode 1 Normal mode ●○○ 2 Input signal waiting mode Toggle change for input mode. Terminals not selected in INPUT SELECT cannot be selected. ○○ PC DVI-D "ERR" when AV DVI-D is selected for DVI of INPUT SELECT. PC D-SUB AV COMPONENT "ERR" when PC RGB is selected for BNC of INPUT SELECT. AV VIDEO PC RGB "ERR" when AV COMPONENT is selected for BNC of INPUT SELECT. AV DVI-D "ERR" when PC DVI-D is selected for DVI of INPUT SELECT. AV S-VIDEO AV HDMI "ERR" when PC HDMI is selected for HDMI of INPUT SELECT. PC HDMI "ERR" when AV HDMI is selected for HDMI of INPUT SELECT. 1 PC DVI-D ○○ 2 PC D-SUB 3 AV COMPONENT 4 AV VIDEO 6 PC RGB 7 AV DVI-D ●○○ 8 AV S-VIDEO 9 AV HDMI 10 PC HDMI SCREEN menu Auto CLOCK Function Command Direction ASNC W CLCK WR PHASE positioning size RESOLUTION RESET E 22 PHSE WR Position of HPOS WR the longest direction Position of VPOS WR the shortest direction Position of HSIZ WR the longest direction Position of VSIZ WR the shortest direction Longest direction resolution HRES WR Shortest direction resolution VRES WR ARST W Parameter 1 0-1200 0-63 0-100 0-100 0-100 0-100 300-1920 200-1200 1 Reply Control/Response contents When the input mode is PC D-SUB, PC RGB. 0-1200 When the input mode is PC D-SUB, PC RGB. Varies depending on the signal. 0-63 When the input mode is PC D-SUB, PC RGB. 0-100 0-800 on PC D-SUB, PC RGB. Varies depending on the signal. 0-100 0-200 on PC D-SUB, PC RGB. Varies depending on the signal. 0-100 0-100 300-1920 When the input mode is PC D-SUB, PC RGB. Only even numbers are valid for parameters. Varies depending on the signal. 200-1200 *2 *1 (A) (B) - ○○

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

E
22
RS-232C command table
How to read the command table
Command:
Command field (See page 18.)
Direction:
W When the “Parameter” is set in the parameter field (see page 18), the command functions as described
under “Control/Response Contents”.
R
The returned value indicated under “Reply” can be obtained by setting “????”, “
?” or “???+”
(repeater control) in the parameter field (see page 18).
Parameter:
Parameter field (See page 18.)
Reply:
Response (Returned value)
*1:
“●” indicates a command which can be used in power standby mode regardless of the STANDBY MODE
setting.
“○” indicates command which can be used in power standby mode when STANDBY MODE is set to
STANDARD. (It cannot be used in the power standby mode when LOW POWER is selected.)
“–” indicates a command which cannot be used in power standby mode.
*2:
PN-ZB01 (optional) limitations
(A) When PN-ZB01 (optional) is not attached, (B) When PN-ZB01 (optional) is attached.
○ : The command can be used.
- : Error (ERR)
Power control/Input mode selection
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
*2
(A) (B)
POWER CONTROL
POWR
W
0
Switches to standby mode.
1
Returns from standby mode.
R
0
Standby mode
1
Normal mode
2
Input signal waiting mode
INPUT MODE SELECTION
INPS
W
0
Toggle change for input mode. Terminals not selected in INPUT SELECT
cannot be selected.
1
PC DVI-D
“ERR” when AV DVI-D is selected for DVI of INPUT SELECT.
-
2
PC D-SUB
3
AV COMPONENT
“ERR” when PC RGB is selected for BNC of INPUT SELECT.
-
4
AV VIDEO
-
6
PC RGB
“ERR” when AV COMPONENT is selected for BNC of INPUT SELECT.
-
7
AV DVI-D
“ERR” when PC DVI-D is selected for DVI of INPUT SELECT.
-
8
AV S-VIDEO
-
9
AV HDMI
“ERR” when PC HDMI is selected for HDMI of INPUT SELECT.
10
PC HDMI
“ERR” when AV HDMI is selected for HDMI of INPUT SELECT.
R
1
PC DVI-D
2
PC D-SUB
3
AV COMPONENT
4
AV VIDEO
6
PC RGB
7
AV DVI-D
8
AV S-VIDEO
9
AV HDMI
10
PC HDMI
SCREEN menu
Function
Command
Direction
Parameter
Reply
Control/Response contents
*1
*2
(A) (B)
AUTO
ASNC
W
1
When the input mode is PC D-SUB, PC RGB.
-
CLOCK
CLCK
WR
0-1200
0-1200
When the input mode is PC D-SUB, PC RGB.
Varies depending on the signal.
PHASE
PHSE
WR
0-63
0-63
When the input mode is PC D-SUB, PC RGB.
POSITIONING
POSITION OF
THE LONGEST
DIRECTION
HPOS
WR
0-100
0-100
0-800 on PC D-SUB, PC RGB.
Varies depending on the signal.
POSITION OF
THE SHORTEST
DIRECTION
VPOS
WR
0-100
0-100
0-200 on PC D-SUB, PC RGB.
Varies depending on the signal.
SIZE
POSITION OF
THE LONGEST
DIRECTION
HSIZ
WR
0-100
0-100
POSITION OF
THE SHORTEST
DIRECTION
VSIZ
WR
0-100
0-100
RESOLUTION
LONGEST
DIRECTION
RESOLUTION
HRES
WR
300-1920
300-1920
When the input mode is PC D-SUB, PC RGB.
Only even numbers are valid for parameters.
Varies depending on the signal.
SHORTEST
DIRECTION
RESOLUTION
VRES
WR
200-1200
200-1200
RESET
ARST
W
1
Controlling the Monitor with a PC (RS-232C)