Sony STRDG820 Operating Instructions - Page 36

AUTO CAL menu parameters, When you select WARN CHECK

Page 36 highlights

•Code 31 1 Press , then follow the instructions from step 1 of "Performing Auto Calibration". •Code 32, 33 1 When you press , "RETRY? YES" appears. 2 Press V/v to select "RETRY? YES", then press . 3 Follow the instructions from step 2 of "Performing Auto Calibration". When you select "WARN CHECK" If a warning on the measurement result is present, detailed information is displayed. Press to return to step 1 of "Confirming/saving the measurement results" (page 33). * You can select this parameter only when you have performed the Auto Calibration and saved the settings. xPOSITION (Position) You can register 3 patterns as position 1, 2 and 3 (POS. 1, POS. 2 and POS. 3), depending on the seating position, listening environment and measurement conditions. You can also load the registered setting. x NAME IN (Naming inputs) You can rename the position name. For details, see "Naming inputs" (page 87). AUTO CAL menu parameters You can use the AUTO CAL menu to make various adjustments for Auto Calibration settings and to name inputs. Select "AUTO CAL" in the amplifier menus. For details on adjusting the parameters, see "Navigating through menus" (page 42) and "Overview of the menus" (page 43). x A.CAL START (Auto Calibration) x CAL TYPE (Calibration type)* • FULL FLAT Makes the measurement of frequency from each speaker flat. • ENGINEER Sets the frequency characteristics to a set that matches that of the Sony listening room standard. • FRONT REF Adjusts the characteristics of all speakers to match the characteristics of the front speaker. • OFF Sets the Auto Calibration equalizer level to off. 36US

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108

36
US
•Code 31
1
Press
, then follow the instructions from step
1 of “Performing Auto Calibration”.
•Code 32, 33
1
When you press
, “RETRY? YES” appears.
2
Press
V
/
v
to select “RETRY? YES”, then press
3
Follow the instructions from step 2 of
“Performing Auto Calibration”.
When you select “WARN CHECK”
If a warning on the measurement result is
present, detailed information is displayed.
Press
to return to step 1 of
“Confirming/saving the
measurement results” (page 33).
You can use the AUTO CAL menu to make
various adjustments for Auto Calibration
settings and to name inputs.
Select “AUTO CAL” in the amplifier menus.
For details on adjusting the parameters, see
“Navigating through menus” (page 42) and
“Overview of the menus” (page 43).
x
A.CAL START (Auto Calibration)
x
CAL TYPE (Calibration type)
*
FULL FLAT
Makes the measurement of frequency from
each speaker flat.
• ENGINEER
Sets the frequency characteristics to a set
that matches that of the Sony listening room
standard.
FRONT REF
Adjusts the characteristics of all speakers to
match the characteristics of the front
speaker.
• OFF
Sets the Auto Calibration equalizer level to
off.
* You can select this parameter only when you have
performed the Auto Calibration and saved the
settings.
x
POSITION (Position)
You can register 3 patterns as position 1, 2
and 3 (POS. 1, POS. 2 and POS. 3),
depending on the seating position, listening
environment and measurement conditions.
You can also load the registered setting.
x
NAME IN (Naming inputs)
You can rename the position name. For
details, see “Naming inputs” (page 87).
AUTO CAL menu parameters