Description, Available settings, Default settings, In/Out settings, ON/OFF settings, Battery
View all Tripp Lite 5P3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
2. Presentation In/Out settings ON/OFF settings Battery settings Description Load segments Auto shutdown delay Overload prealarm Cold start Forced reboot Auto restart Energy saving Sleep mode Remote command Automatic battery test Low battery warning Restart battery level Battery charge mode Deep discharge protection Available settings Default settings [Disable] [0s] [1 s] [2 s]...[65354 s] Group 1: Disable During a power outage, Group 2: Disable authorizes UPS to turn off power to equipment connected to Group 1 and/or Group 2 outlets. This feature allows the shedding of non-critical loads in order to conserve battery power for critical loads connected to the Primary group. [10 %] [15 %] [20 %] ... [100 %] [105 %] [105 %] Sets critical percentage of load where alarm overload alarm occurs. [Disable] [Enable] Authorizes the product to start on battery power. Enable [Disable] [Enable] If mains recover during a shutdown sequence: If set to Enable, shutdown sequence will complete and wait 10 seconds prior to restart, If set to Disable, shutdown sequence will not complete and restart will occur immediately. Enable [Disable] [Enable] Authorizes the product to restart automatically when mains recovers after a complete battery discharge. Enable [Disable] [Enable] If Enable, UPS will shutdown after 5 min. of back-up time, if no load is detected on the output. Disable [Disable] [Enable] If disable, LCD and communication will turn OFF immediately after UPS is OFF. If enable, LCD and communication stays ON 1h30 min after UPS is OFF. Disable [Disable] [Enable] If enable, shutdown or restart commands from software are authorised. Enable [No test] [Every day] [Every week] Every week [Every month] (in constant charge) Available only if battery charge mode otherwise following ABM is set to constant charge. [1 %] [2 %] ... [100 %] The alarm triggers when the set percentage of battery capacity is reached during a back-up time. 20 % [1 %] [2 %] ... [100 %] 0 % If set, automatic restart will occur only when percentage of battery charge is reached. [ABM cycling] [Constant charge] ABM cycling [Yes] [No] Yes If set to Yes, the UPS automatically prevents battery from deep discharge by adapting end of back-up time voltage threshold. Page 12 614-03898-00_EN