Tripp Lite 5P3000 Eaton 5P1500RT 5P2200RT 5P2200 5P3000RT 5P3000 UPS Installat - Page 16

Communication ports

Page 16 highlights

3. Installation 3.5 Communication ports Connection of RS232 or USB communication port (optional) The RS232 and USB communication ports cannot operate simultaneously. 1. Connect the RS232 16 or USB 17 communication cable to 17 the serial or USB port on the computer equipment. 2. Connect the other end of the 16 communication cable 16 or 17 to the USB 1 or RS232 2 communication port on the UPS. The UPS can now communicate with EATON power management software. Installation of the communication cards (optional, standard on the Netpack versions) It is not necessary to shutdown the UPS before installing a communication card. 1. Remove the slot cover 4 secured by screws. 2. Insert the communication card in the slot. 3. Secure the card cover with the 2 screws. Characteristics of the contact communication port (optional) pp Pins 1, 3, 4, 5, 6, 10: not used pp Pin 2: common (user) pp Pin 7: low battery pp Pin 8: operation on battery power pp Pin 9: UPS ON, equipment supplied n.o.: normally open contact Page 16 When a signal is activated, the contact is closed between the common (pin 2) and the pin for the corresponding signal. Contact characteristics (optocoupler) pp Voltage: 48 V DC max pp Current: 25 mA max pp Power: 1.2 W 614-03898-00_EN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

Page 16
614-03898-00_EN
3. Installation
3.5 Communication ports
Connection of RS232 or USB communication port
(optional)
The RS232 and USB communication ports cannot operate simultaneously.
16
17
1.
Connect the RS232
16
or USB
17
communication cable to
the serial or USB port on
the computer equipment.
2.
Connect the other end of the
communication cable
16
or
17
to the USB
1
or RS232
2
communication port on
the UPS.
The
UPS
can now communicate
with EATON power management
software.
Installation of the communication cards
(optional, standard on the Netpack versions)
It is not necessary to shutdown
the UPS before installing
a communication card.
1.
Remove the slot cover
4
secured by screws.
2.
Insert the communication
card in the slot.
3.
Secure the card cover with
the 2 screws.
Characteristics of the contact communication port
(optional)
Pins 1, 3, 4, 5, 6, 10: not used
p
Pin 2: common (user)
p
Pin 7: low battery
p
Pin 8: operation on battery
p
power
Pin 9: UPS ON, equipment
p
supplied
n.o.: normally open contact
When a signal is activated, the contact is closed between the common (pin 2) and the pin
for the corresponding signal.
Contact characteristics (optocoupler)
Voltage: 48 V DC max
p
Current: 25 mA max
p
Power: 1.2 W
p