3Ware 9500S-8MI Installation Guide - Page 54

Specifying a Hot Spare, Available Drives list.

Page 54 highlights

Configuring Units Depending on the RAID configuration you are creating, initialization of the unit may begin immediately. For details, see "Initializing Units" on page 49. Specifying a Hot Spare You can designate one of the Available Drives as a hot spare in 3BM. If a hot spare is specified and a redundant unit degrades, an event notification will be generated. The hot spare will automatically replace the failed drive without user intervention. To specify a hot spare 1 In the list of Available Drives, highlight the drive to use. 2 Type s to specify that the selected drive will be the hot spare. You'll see the words "Hot Spare" appear next to the drive in the Available Drives list. Figure 16. Hot Spare Indicated 46 3ware 9000 Series Serial ATA RAID Controller Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

Configuring Units
46
3ware 9000 Series Serial ATA RAID Controller Installation Guide
Depending on the RAID configuration you are creating,
initialization of the unit may begin immediately. For details, see
“Initializing Units” on page 49.
Specifying a Hot Spare
You can designate one of the
Available Drives
as a hot spare in
3BM
.
If a hot spare is specified and a redundant unit degrades, an
event notification will be generated. The hot spare will
automatically replace the failed drive without user intervention.
To specify a hot spare
1
In the list of
Available Drives
, highlight the drive to use
.
2
Type
s
to specify that the selected drive will be the hot spare.
You’ll see the words “Hot Spare” appear next to the drive in the
Available Drives list.
Figure 16.
Hot Spare Indicated