Removing and Replacing Enclosure Components Removing an APC Before you remove an APC, ensure that you have a replacement module ready for immediate installation so that proper cooling and airflow are maintained. Failed APCs must be replaced within five minutes, or the system does an orderly shut-down. To remove an APC from the Storage Enclosure: 1 Power off the failed APC module and remove the power cable. If the enclosure is powered on, the fans in both APC modules switch to high speed. The cooling fans in the failed APC are now running on power supplied by the other APC module. 2 Using a Phillips-head screwdriver, loosen the two screws on the APC module that hold the handles in place. 3 Gently push down on the handles to disengage the APC module from the enclosure. 4 Using the handles, gently slide the APC out of the enclosure, as shown in Figure 4-2. Slide APC out, using its handles Figure 4-2 Sliding the APC from the Enclosure Warning: To avoid electrical shock, do not insert any instruments or tools into the open APC slot. Note: Do not use the handles to lift or carry APC modules. 4-5