Amana ART318FFDW Installation Instructions - Page 12
Mounting the water valve
View all Amana ART318FFDW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
Mounting the water valve Refer to the diagram below for the following steps. 1. Locate the 2-pin water valve solenoid connector (with the brown and two white wires) that is taped to the main wiring harness at the lower right corner of the rear access (see DETAIL A). 2. Refer to DETAIL B and insert the 2-pin connector over the water valve solenoid terminals as far as possible (if the harness is not long enough, break the tape holding it to the main harness). You can position the connector with the wires at either terminal. 3. Refer to DETAIL B and mount the water valve to the mounting holes in the cabinet frame with two 1/2" hex-head machine screws. Make sure that you tighten these two screws securely. NOTE: For side by side models with a metal access cover, the valve is mounted to the valve bracket previously installed instead of directly to the cabinet. Mounting the water valve Brown (2) White DETAIL A 2-pin connector DDEETTAAIILL CB 22-p-pinin ccoonnnneeccttoor r WatWeravtaelrvevalve 12 1mm1/⁄a22"c"ahchhiehnexeixn-h-sehecesraeacdwdresws