Asus AP6000 Hardware Reference - Page 15
Circulation System, Fan Replacement
View all Asus AP6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
II. System Components Circulation System The server's air circulation system is comprised of five 3 inch (8 cm) fans mounted on a metal fan module. The circulation system cools the hard disk drives by bringing fresh air in from the front and forcing the hot air out through the back. It is important to keep the air surrounding the hard disk drives below 122˚F (50˚C) to prevent hard disk failures. Fan Replacement The fan module can be removed by pulling the handle and inserted by pushing. The handle must be in the out position to insert the fan module. The individual fans are secured by two clips and two hooks. To release these clips, use a screw driver to push these clips in and then slide the fan out. If an individual fan fails, remove the fan and send it back to the vendor for replacement. If all five fans fail, it may be that the fan control board needs replacing, remove the control board and send it back to your vendor for replacement. Fan Module Release Handle Air Inlet Vents (along full length of door) II. Components Circulation System Removing or inserting the fan module Fan 1 Fan 2 Release Handle (from chassis) Fan 3 Fan 4 Fan Module Control Board Fan 5 Fan module When replacing fans, be sure that the fan rotations are in the same direction. Use the manufacturer's sticker on one side of the fan as a reference as to the side. Air flows from the front of the server to the rear. Fan Replacement (Reverse side) AP6000 Hardware Reference Guide 15