Behringer NEUTRON Manual - Page 18

Eurorack Installation

Page 18 highlights

18 NEUTRON User Manual 6. Eurorack Installation The Neutron synthesizer can be taken out of its factory chassis and fitted into a standard Eurorack case (not supplied). We recommend that this procedure is undertaken only by an experienced service technician, to prevent personal injury, or damage to the unit. The Eurorack case will need its own suitable power supply unit to power the Neutron synthesizer. X58 A 10-pin connector on the rear of the main PCB of the Neutron allows the +12 VDC power supply connection to be made. A 10-pin to 16-pin adapter ribbon cable is supplied to connect to your power supply. Before proceeding, make sure that your power supply is capable of supplying +12 VDC, 1 Amp. X59 Make sure that the connections using the supplied adapter cable will supply the ground and power to the correct pins. 6.1 Procedure Follow all steps in the order in which they are presented. 1. Disconnect the power cord and all other connections to the Neutron. X60 2. Undo the 8 screws on the top panel as shown. There is no need to undo any other screws. 3. Carefully lift the top panel assembly and turn it over so the PCB is facing upwards. Be careful not to pull on the cable from the lower side of the main PCB. 4.Disconnect the 24-pin cable from the side of the main PCB of the Neutron, X58 and remove the assembly from the chassis. 5. Store the chassis assembly and the power supply adaptor in a dry safe place. 6. Securely connect the 10-pin end P1 of the supplied adapter cable to connector X59 on the Main PCB of the Neutron. 7. Make sure your power supply is turned off and disconnected from the AC mains. 8. Make sure that your power supply will supply a 12 V voltage to the pins of the connector, as shown in the diagram. 9. Securely connect the 10-pin end P2 of the supplied adapter cable to your power supply, and double check all connections are correct. 10. Securely install the Neutron Synthesizer into your Eurorack, using 8 screws in the front panel. 11. Perform a full system test and safety test before using the Neutron. 12. The 3.5 mm OUTPUT connector on the top panel is used instead of the rear output which is no longer present. Disconnect from Main PCB +12 VDC Pins 3 to 8 Ground No Connection

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

18
NEUTRON User Manual
6.
Eurorack Installation
The Neutron synthesizer can be taken out of its factory chassis and fitted into a
standard Eurorack case (not supplied).
We recommend that this procedure is undertaken only by an experienced service
technician, to prevent personal injury, or damage to the unit. The Eurorack case
will need its own suitable power supply unit to power the Neutron synthesizer.
A 10-pin connector on the rear of the main PCB of the Neutron allows the
+12 VDC power supply connection to be made. A 10-pin to 16-pin adapter ribbon
cable is supplied to connect to your power supply.
Before proceeding, make sure that your power supply is capable of supplying
+12 VDC, 1 Amp.
Make sure that the connections using the supplied adapter cable will supply the
ground and power to the correct pins.
6.1
Procedure
Follow all steps in the order in which they are presented.
1. Disconnect the power cord and all other connections to the Neutron.
2. Undo the 8 screws on the top panel as shown. There is no need to undo any
other screws.
3. Carefully lift the top panel assembly and turn it over so the PCB is facing
upwards. Be careful not to pull on the cable from the lower side of the main PCB.
4.Disconnect the 24-pin cable from the side of the main PCB of the Neutron, X58
and remove the assembly from the chassis.
5. Store the chassis assembly and the power supply adaptor in a dry safe place.
6. Securely connect the 10-pin end P1 of the supplied adapter cable to connector
X59 on the Main PCB of the Neutron.
7. Make sure your power supply is turned off and disconnected from the AC mains.
8. Make sure that your power supply will supply a 12 V voltage to the pins of the
connector, as shown in the diagram.
9. Securely connect the 10-pin end P2 of the supplied adapter cable to your power
supply, and double check all connections are correct.
10. Securely install the Neutron Synthesizer into your Eurorack, using 8 screws in
the front panel.
11. Perform a full system test and safety test before using the Neutron.
12. The 3.5 mm OUTPUT connector on the top panel is used instead of the rear
output which is no longer present.
+12 VDC
No Connection
Pins 3 to 8 Ground
X58
X59
X60
Disconnect from
Main PCB