BenQ 2720S Service Guide - Page 32

Main Flow Chart of Film Scanner

Page 32 highlights

5.5.3 CCD/Home Sensor Board There is one connector on the CCD board in 2740S scanner (referring to figure 5-9), the connector description is as following. 2740S CC D PC B CCD J1 Figure 5-9 5.6 Main Flow Chart of Film Scanner Start (power-on) 1. Initial system and CPU parameter 2. Reset components condition 3. Reset communication mode System self test: 1. test ROM 2. test all RAM 3. check scanner motor and position sensor 4. test CCD and lamp 5. test analog processor ICs Check burn-in mode? Yes Burn-in test Initial communication mode Next scan Receiving host command and data Send target message to host "START SCAN" command Calibration Adjust scanning parameters: 1. brightness 2. contrast 3. shadow-highlight 4. gamma correction 5. multi bit and single bit 6. window mode 7. line art and halftone 8. scalling and resolution 9. matrix operation Send scanned data (* control scanning timing and handshaking timing *) End of scan Next scan Stop (power-off) Figure 5-10 Main Flow Chart of Film Scanner 5-10 API Confidential No Copy/Reproduction allowed Electrical Systems

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

5.5.3 CCD/Home Sensor Board
There is one connector on the CCD board in 2740S scanner (referring to
figure 5-9), the connector description is as following.
2740S C C D P C B
J1
CCD
Figure 5-9
5.6 Main Flow Chart of Film Scanner
Start (power-on)
1. Initial system and CPU parameter
2. Reset components condition
3. Reset communication mode
System self test:
1. test ROM
2. test all RAM
3. check scanner motor and
position sensor
4. test CCD and lamp
5. test analog processor ICs
Check burn-in mode?
Yes
Burn-in test
Initial communication mode
Receiving host command and data
Send target message to host
"START SCAN" command
Calibration
Adjust scanning parameters:
1. brightness
2. contrast
3. shadow-highlight
4. gamma correction
5. multi bit and single bit
6. window mode
7. line art and halftone
8. scalling and resolution
9. matrix operation
Send scanned data
(* control scanning timing and
handshaking timing *)
End of scan
Next scan
Next scan
Stop (power-off)
Figure 5-10 Main Flow Chart of Film Scanner
5-10
API Confidential
Electrical Systems