BenQ 2720S Service Guide - Page 41
Maintenance
View all BenQ 2720S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 41 highlights
Chapter 7 Maintenance This chapter gives step by step instructions for maintaining the 2740S film scanner. 7.1 Precaution Make sure that you unplug the film scanner before disassembling. Unless otherwise specified, reassemble the scanner by reversing the disassembly procedure. Do not disassemble the CCD board and lens. If it is necessary to plug in the adapter cord and operate the scanner after it is disassembled, pay special attention to the following: A. Keep your hands and clothing well away from the operating or moving parts such as scan module, gear train ...etc. B. Never touches the terminals of the electrical and high-voltage parts. Unplug the connector by holding the connector housing. Pulling the cable cord may cause poor connection. Turn the power off first when unplug the connector on the scanner circuit board. Never turn the power on if there is no shading on the lamp. 7.2 Housing Section To removing housing A. Remove the two screws in Figure 7-1. B. Open the both side of the housing by the arrow direction, then pull out the housing. CAUTION: Make sure there is not a strip holder or slide holder inserted Maintenance API Confidential 7-1 No Copy/Reproduction allowed