BenQ 2720S Service Guide - Page 37

Trouble-shooting

Page 37 highlights

Chapter 6 Trouble-shooting 6.1 Error Code Identification from "Status" LED When the LED flashes: "1" time - FLASH or Firmware Upgrade error "2" times - DATA RAM error "3" times - Reserved "4" times - ASIC (AP2106) error "5" times - Line Motor/Home Sensor error "6" times - Auto Focus Motor/Sensor error "7" times - DC Offset error "8" times - Lamp/CCD error 6.2 No Function after Power On: ⊙ Power input --- Regulators/Power Cord/Power Switch ⊙ U3 --- CPU 80C32 ⊙ Y1 --- XTAL 16MHZ ⊙ U8 --- IC 74HC04D ⊙ U2 --- ASIC(AP2106A) 6.3 Cannot Link with Host Computer: ⊙ Interface - SCSI Cable/Loose Plug ⊙ U2 --- ASIC(AP2106A) ⊙ U6 --- DRAM ⊙ U8 --- IC 74HC04D Trouble-shooting API Confidential 6-1 No Copy/Reproduction allowed

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67

Chapter 6 Trouble-shooting
6.1 Error Code Identification from “Status” LED
When the LED flashes:
“1” time - FLASH or Firmware Upgrade error
“2” times - DATA RAM error
“3” times – Reserved
“4” times – ASIC (AP2106) error
“5” times - Line Motor/Home Sensor error
“6” times – Auto Focus Motor/Sensor error
“7” times - DC Offset error
“8” times - Lamp/CCD error
6.2 No Function after Power On:
Power input --- Regulators/Power Cord/Power Switch
U3 --- CPU 80C32
Y1 --- XTAL 16MHZ
U8 --- IC 74HC04D
U2 --- ASIC(AP2106A)
6.3 Cannot Link with Host Computer:
Interface – SCSI Cable/Loose Plug
U2 --- ASIC(AP2106A)
U6 --- DRAM
U8 --- IC 74HC04D
Trouble-shooting
API Confidential
6-1
No Copy/Reproduction allowed