Bosch VDN-498V03-21 User Manual - Page 31

Shutter/AGC submenu

Page 31 highlights

34 en | Configuration FlexiDome2X 5.5.3 Item Shutter/AGC submenu Selection Description Shutter AES, FL, Fixed AES (auto-shutter) - the camera automatically sets the optimum shutter speed. FL - flickerless mode avoids interference from light sources. FIXED - allows a user defined shutter speed. Default (AES) shutter or Fixed shutter 1/50 (PAL), 1/60 (NTSC) 1/100, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/5000, 1/10K In AES mode, the camera tries to maintain the selected shutter speed as long as the light level of the scene is high enough. In Fixed mode, selects shutter speed. Actual shutter Displays the actual shutter value from the camera to help compare lighting levels and optimum shutter speed during set-up. Gain control On, Fixed On - the camera automatically sets the gain to the lowest possible value needed to maintain a good picture. Fixed - sets Fixed AGC value. Maximum AGC or Fixed AGC 0 to 30 dB Selects the maximum value the gain can have during AGC operation. Selects the gain setting for Fixed gain operation (0 is no gain). Actual AGC Displays the actual AGC value from the camera to help compare gain level with lighting levels and picture performance. AR18-08-B010 | v1.0 | 2009.03 Installation Manual Bosch Security Systems

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

34
en | Configuration
FlexiDome2X
AR18-08-B010 | v1.0 | 2009.03
Installation Manual
Bosch Security Systems
5.5.3
Shutter/AGC submenu
Item
Selection
Description
Shutter
AES, FL, Fixed
AES (auto-shutter) - the camera automatically
sets the optimum shutter speed.
FL - flickerless mode avoids interference from
light sources.
FIXED - allows a user defined shutter speed.
Default (AES)
shutter
or
Fixed shutter
1/50 (PAL),
1/60 (NTSC)
1/100, 1/120,
1/250,
1/500,
1/1000,
1/2000,
1/5000,
1/10K
In AES mode, the camera tries to maintain the
selected shutter speed as long as the light
level of the scene is high enough.
In Fixed mode, selects shutter speed.
Actual shutter
Displays the actual shutter value from the
camera to help compare lighting levels and
optimum shutter speed during set-up.
Gain control
On, Fixed
On - the camera automatically sets the gain to
the lowest possible value needed to maintain
a good picture.
Fixed - sets Fixed AGC value.
Maximum AGC
or
Fixed AGC
0 to 30 dB
Selects the maximum value the gain can have
during AGC operation.
Selects the gain setting for Fixed gain
operation (0 is no gain).
Actual AGC
Displays the actual AGC value from the
camera to help compare gain level with
lighting levels and picture performance.