Bosch VJT-X10S Operation Manual - Page 60

TCP HTTP port, Destination IP address

Page 60 highlights

60 en | Configuration Using a Web Browser VideoJet X10 By setting Follows input 1 the unit maintains the connection that has been automatically established for as long as an alarm exists on alarm input 1. NOTICE! i In the default setting, Stream 2 is transmitted for alarm connections. Bear this fact in mind when assigning the profile (see Section 5.19 Advanced Mode: Encoder Profile, page 47). Number of destination IP address Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit contacts the remote stations one after the other in the numbered sequence until a connection is made. Destination IP address For each number, enter the corresponding IP address for the desired remote station. Destination password If the remote station is password protected, enter the password here. In this page, you can save a maximum of ten destination IP addresses and hence up to ten passwords for connecting to remote stations. If connections to more than ten remote stations are to be possible, for example when initiating connections via higher-ranking systems such as VIDOS or Bosch Video Management System, you can store a general password here. The VideoJet X10 can use this general password to connect to all remote stations protected with the same password. In this case, proceed as follows: 1. Select 10 from the Number of destination IP address list field. 2. Enter the address 0.0.0.0 in the Destination IP address field. 3. Enter your chosen password in the Destination password field. 4. Define this password as the user password for all remote stations to which a connection is to be possible. NOTICE! i If you enter the destination IP address 0.0.0.0 for destination 10, this VideoJet X10 address will no longer be used for the tenth attempt at automatic connection in the event of an alarm. The parameter is then used only to save the general password. Video transmission If the unit is operated behind a firewall, TCP (HTTP port) should be selected as the transfer protocol. For use in a local network, select UDP. CAUTION! Please note that in some circumstances, a larger bandwidth must be available on the network ! for additional video images in the event of an alarm, in case Multicast operation is not possible. To enable Multicast operation, select the UDP option for the Video transmission parameter here and on the Network page (see Section Video transmission, page 78). Remote port Depending on the network configuration, select a browser port here. The ports for HTTPS connections will be available only if the On option is selected in the SSL encryption parameter. Video output If you know which unit is being used as the receiver, you can select the analog video output to which the signal should be switched. If the destination unit is unknown, it is advisable to select the First available option. In this case, the image is placed on the first free video DOC | V4.0 | 2009.06 Installation and Operating Manual Bosch Security Systems

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

60
en | Configuration Using a Web Browser
VideoJet X10
DOC | V4.0 | 2009.06
Installation and Operating Manual
Bosch Security Systems
By setting
Follows input 1
the unit maintains the connection that has been automatically
established for as long as an alarm exists on alarm input 1.
Number of destination IP address
Specify the numbers of the IP addresses to be contacted in the event of an alarm. The unit
contacts the remote stations one after the other in the numbered sequence until a connection
is made.
Destination IP address
For each number, enter the corresponding IP address for the desired remote station.
Destination password
If the remote station is password protected, enter the password here.
In this page, you can save a maximum of ten destination IP addresses and hence up to ten
passwords for connecting to remote stations. If connections to more than ten remote stations
are to be possible, for example when initiating connections via higher-ranking systems such as
VIDOS or Bosch Video Management System, you can store a general password here. The
VideoJet X10 can use this general password to connect to all remote stations protected with
the same password. In this case, proceed as follows:
1.
Select
10
from the
Number of destination IP address
list field.
2.
Enter the address
0.0.0.0
in the
Destination IP address
field.
3.
Enter your chosen password in the
Destination password
field.
4.
Define this password as the
user
password for all remote stations to which a connection
is to be possible.
Video transmission
If the unit is operated behind a firewall,
TCP (HTTP port)
should be selected as the transfer
protocol. For use in a local network, select
UDP
.
Remote port
Depending on the network configuration, select a browser port here. The ports for HTTPS
connections will be available only if the
On
option is selected in the
SSL encryption
parameter.
Video output
If you know which unit is being used as the receiver, you can select the analog video output to
which the signal should be switched. If the destination unit is unknown, it is advisable to
select the
First available
option. In this case, the image is placed on the first free video
i
NOTICE!
In the default setting, Stream 2 is transmitted for alarm connections. Bear this fact in mind
when assigning the profile (see
Section 5.19 Advanced Mode: Encoder Profile, page 47
).
i
NOTICE!
If you enter the destination IP address 0.0.0.0 for destination 10, this VideoJet X10 address
will no longer be used for the tenth attempt at automatic connection in the event of an alarm.
The parameter is then used only to save the general password.
!
CAUTION!
Please note that in some circumstances, a larger bandwidth must be available on the network
for additional video images in the event of an alarm, in case Multicast operation is not
possible. To enable Multicast operation, select the
UDP
option for the
Video transmission
parameter here and on the
Network
page (see
Section
Video transmission, page 78
).