Bosch VJT-X10S Operation Manual - Page 61

Decoder, SSL encryption, Remote port, Auto-connect, Audio, NOTICE

Page 61 highlights

VideoJet X10 i i i Configuration Using a Web Browser | en 61 output. This is an output on which there is no signal. The connected monitor only displays images when an alarm is triggered. If you select a particular video output and a split image is set for this output on the receiver, you can also select from Decoder the decoder in the receiver that is to be used to display the alarm image. NOTICE! Refer to the destination unit documentation concerning image display options and available video outputs. Decoder Select a decoder of the receiver to display the alarm image. The decoder selected has an impact on the position of the image in a split screen. For example, you can specify via a VIP XD that the upper-right quadrant should be used to display the alarm image by selecting decoder 2. SSL encryption The data for the connection, for example the password, can be securely transmitted with SSL encryption. If you have selected the On option, only encrypted ports are offered in the Remote port parameter. NOTICE! Please note that the SSL encryption must be activated and configured at both ends of a connection. This requires the appropriate certificates to be uploaded onto the VideoJet X10 (see Section Maintenance log, page 85). You can activate and configure encryption of the media data (video, audio and metadata) on the Encryption page (see Section 5.42 Advanced Mode: Encryption, page 84). Auto-connect Select the On option to automatically re-establish a connection to one of the previously specified IP addresses after each reboot, after a connection breakdown or after a network failure. NOTICE! In the default setting, Stream 2 is transmitted for automatic connections. Bear this fact in mind when assigning the profile (see Section 5.19 Advanced Mode: Encoder Profile, page 47). Audio Select the On option if you wish to additionally transmit a standalone G.711 encoded audio stream with alarm connections. Bosch Security Systems Installation and Operating Manual DOC | V4.0 | 2009.06

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

VideoJet X10
Configuration Using a Web Browser | en
61
Bosch Security Systems
Installation and Operating Manual
DOC | V4.0 | 2009.06
output. This is an output on which there is no signal. The connected monitor only displays
images when an alarm is triggered. If you select a particular video output and a split image is
set for this output on the receiver, you can also select from
Decoder
the decoder in the
receiver that is to be used to display the alarm image.
Decoder
Select a decoder of the receiver to display the alarm image. The decoder selected has an
impact on the position of the image in a split screen. For example, you can specify via a VIP XD
that the upper-right quadrant should be used to display the alarm image by selecting decoder
2.
SSL encryption
The data for the connection, for example the password, can be securely transmitted with SSL
encryption. If you have selected the
On
option, only encrypted ports are offered in the
Remote port
parameter.
You can activate and configure encryption of the media data (video, audio and metadata) on
the
Encryption
page (see
Section 5.42 Advanced Mode: Encryption, page 84
).
Auto-connect
Select the
On
option to automatically re-establish a connection to one of the previously
specified IP addresses after each reboot, after a connection breakdown or after a network
failure.
Audio
Select the
On
option if you wish to additionally transmit a standalone G.711 encoded audio
stream with alarm connections.
i
NOTICE!
Refer to the destination unit documentation concerning image display options and available
video outputs.
i
NOTICE!
Please note that the SSL encryption must be activated and configured at both ends of a
connection. This requires the appropriate certificates to be uploaded onto the VideoJet X10
(see
Section
Maintenance log, page 85
).
i
NOTICE!
In the default setting, Stream 2 is transmitted for automatic connections. Bear this fact in
mind when assigning the profile (see
Section 5.19 Advanced Mode: Encoder Profile, page 47
).