Bosch WTMC5521UC Operating, Care, Installation (all languages) - Page 7

Warning, Caution - venting

Page 7 highlights

Gas connection d WARNING d Explosion hazard! Use a new AGA or CSA approved gas supply line. Install a shutĆoff valve. Securely tighten all gas connections. Have a qualified person make sure gas pressure does not exceed 14 in. W.C./ 3.49 kPa/ 0.506 psig. (Natural and Propane Gas). Example of a qualified person include: - licensed heating personnel, - authorized gas supplier personnel, - authorized service personnel. Failure to do can result in explosion or fire. Risk of death or injury! All gas line connections must be teĆ sted for leaks prior to appliance operation. Apply soapy water to gas line connections and check for forĆ mation of new bubbles. Bubbles inĆ dicate leak! When installing the gas supply to the gas dryer inlet pipe, do not exceed 310 lbf in (35 Nm). d WARNING d Never use an open flame to test for gas leaks. Gas type This gas dryer when equipped for use with NATURAL GAS, will employ an orifice size 46 and have a gas outlet pressure of 3.5 in. W.C. This gas dryer when equipped for use with PROPANE GAS, will employ an orifice size of 1.21 mm, and have a gas outlet pressure of 11 in. W.C. Your dryer must have the correct valve for the type of gas in your home. Valve information is located on the rating plate behind the door below the drum. If the ratingĆplate information does not agree with the type of gas available, contact your dealer or our customer service team (see page 21). Gas supply line 1/2" I.D. pipe is recommended. 3/8" approved tubing is acceptable for lengths under 20 ft (6.1 m) if local codes and gas supplier permit. Must include 1/8" NPT plugged tapping, immediately upstream of the gas connection. A shut off valve must be included: - USA: An individual manual shutĆoff valve must be installed within 6 ft (1.8 m) of the dryer in accordance with the National Fuel Gas Code, ANSI Z223.1. - Canada: An individual manual shutĆoff valve must be installed in accordance with the B149, Installation Codes, CAN/CSA B149.1 and CAN/CSA B149.2. It is recommended that an individual manual shutĆoff valve be installed within 6 ft (1.8 m) of the dryer. 5 43 2 1 1 1 ć 1/2" NPT gas supply line 2 ć Gas shutĆoff valve 3 ć 1/8" NPT plugged tapping 4 ć 3/8" pipe to flare adapter fitting 5 ć 3/8" flexible gas connector (to the dryer) The shutĆoff valve should be easy to reach for opening and closing. Note: The dryer must be checked for proper operation whenever the gas connections have been broken. Dryer gas pipe The gas pipe that comes out through the rear of the pipe thread. dryer has a 3/8" male Connection of the dryer d CAUTION Connection must be made by a qualified technician. The dryer must be disconnected from the gas supply piping system during testing pressure. When using for the first time make sure that there is no air in the piping system. d WARNING d Do not use copper pipes and tubing if connected to natural gas. The connection may be different, according to the supply line type, size and location. If local codes permit, use a flexible stainless steel connector (Design certified by the America Gas Association or CSA International) to connect the dryer. 1 2 To reduce the distance between body sheet and wall install a 3/8" elbow on the gas pipe of the dryer. 1 ć gas pipe (3/8" male pipe thread) 2 ć 3/8" elbow Exhaust air connection d WARNING d 1. To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS. 2. To reduce the risk of fire, do not use ductwork longer than recommended. 3. DO NOT use a plastic or nonĆmetal duct with this dryer. 4. DO NOT use a duct smaller than 4 inches in diameter. 5. DO NOT use exhaust hoods with magnetic latches. 6. DO NOT exhaust the dryer into a chimney, furnace cold air duct, attic, crawl space, or any other ductwork used for venting. 7. DO NOT install a flexible duct in an enclosed wall, ceiling or floor. 8. DO NOT crush or kink the duct. 9. Do clean and inspect the exhaust system on a regular basis; at least once a year. 10. The exhaust duct must terminate in a manner to prevent back drafts or entry of birds or other wildlife. The Bosch dryer must be vented outdoors. To prevent buildĆup of moisture and accumulation of lint indoors, as well as to maintain maximum drying efficiency, it is recommended that the dryer is vented outdoors. Exhaust air outlet on the dryer The dryer is delivered with an exhaust air outlet on the rear of the appliance. To take account of the spatial requirements and an existing exhaust air system, the following connection options are possible for the exhaust air outlet: - on right side of the appliance, - on the underside of the appliance. 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

7
Gas
connection
d
WARNING
d
Explosion
hazard!
Use
a
new
AGA
or
CSA
approved
gas
supply
line.
Install
a
shutĆoff
valve.
Securely
tighten
all
gas
connections.
Have
a
qualified
person
make
sure
gas
pressure
does
not
exceed
14±in.±W.C./
3.49±kPa/
0.506
psig.
(Natural
and
Propane
Gas).
Example
of
a
qualified
person
include:
-
licensed
heating
personnel,
-
authorized
gas
supplier
personnel,
-
authorized
service
personnel.
Failure
to
do
can
result
in
explosion
or
fire.
Risk
of
death
or
injury!
All
gas
line
connections
must
be
teĆ
sted
for
leaks
prior
to
appliance
operation.
Apply
soapy
water
to
gas
line
connections
and
check
for
forĆ
mation
of
new
bubbles.
Bubbles
inĆ
dicate
leak!
When
installing
the
gas
supply
to
the
gas
dryer
inlet
pipe,
do
not
exceed
310
lbf
in
(35
Nm).
d
WARNING
d
Never
use
an
open
flame
to
test
for
gas
leaks.
Gas
type
This
gas
dryer
when
equipped
for
use
with
NATURAL
GAS,
will
employ
an
orifice
size
46
and
have
a
gas
outlet
pressure
of
3.5
in.
W.C.
This
gas
dryer
when
equipped
for
use
with
PROPANE
GAS,
will
employ
an
orifice
size
of
1.21
mm,
and
have
a
gas
outlet
pressure
of
11
in.
W.C.
Your
dryer
must
have
the
correct
valve
for
the
type
of
gas
in
your
home.
Valve
information
is
located
on
the
rating
plate
behind
the
door
below
the
drum.
If
the
ratingĆplate
information
does
not
agree
with
the
type
of
gas
available,
contact
your
dealer
or
our
customer
service
team
(see±page±21).
Gas
supply
line
1
/
2
"
I.D.
pipe
is
recommended.
3
/
8
"
approved
tubing
is
acceptable
for
lengths
under
20±ft
(6.1
m)
if
local
codes
and
gas
supplier
permit.
Must
include
1
/
8
"
NPT
plugged
tapping,
immediately
upstream
of
the
gas
connection.
A
shut
off
valve
must
be
included:
-
USA:
An
individual
manual
shutĆoff
valve
must
be
installed
within
6±ft
(1.8
m)
of
the
dryer
in
accordance
with
the
National
Fuel
Gas
Code,
ANSI
Z223.1.
-
Canada
:
An
individual
manual
shutĆoff
valve
must
be
installed
in
accordance
with
the
B149,
Installation
Codes,
CAN/CSA
B149.1
and
CAN/CSA
B149.2.
It
is
recommended
that
an
individual
manual
shutĆoff
valve
be
installed
within
6±ft
(1.8
m)
of
the
dryer.
1
1
2
3
4
5
1
ć
1
/
2
"
NPT
gas
supply
line
2
ć
Gas
shutĆoff
valve
3
ć
1
/
8
"
NPT
plugged
tapping
4
ć
3
/
8
"
pipe
to
flare
adapter
fitting
5
ć
3
/
8
"
flexible
gas
connector
(to
the
dryer)
The
shutĆoff
valve
should
be
easy
to
reach
for
opening
and
closing.
Note:
The
dryer
must
be
checked
for
proper
operation
whenever
the
gas
connections
have
been
broken.
Dryer
gas
pipe
The
gas
pipe
that
comes
out
through
the
rear
of
the
dryer
has
a
±3
/
8
"
male
pipe
thread.
Connection
of
the
dryer
d
CAUTION
Connection
must
be
made
by
a±qualified
technician.
The
dryer
must
be
disconnected
from
the
gas
supply
piping
system
during
testing
pressure.
When
using
for
the
first
time
make
sure
that
there
is
no
air
in
the
piping
system.
d
WARNING
d
Do
not
use
copper
pipes
and
tubing
if
connected
to
natural
gas.
The
connection
may
be
different,
according
to
the
supply
line
type,
size
and
location.
If
local
codes
permit,
use
a
flexible
stainless
steel
connector
(Design
certified
by
the
America
Gas
Association
or
CSA
International)
to±connect
the
dryer.
1
2
To
reduce
the
distance
between
body
sheet
and
wall
install
3
/
8
"±elbow
on
the
gas
pipe
of
the
dryer.
1
ć
gas
pipe
(
3
/
8
"
male
pipe
thread)
2
ć
3
/
8
"
elbow
Exhaust
air
connection
d
WARNING
d
1.
To
reduce
the
risk
of
fire,
this
dryer
MUST
BE
EXHAUSTED
OUTDOORS.
2.
To
reduce
the
risk
of
fire,
do
not
use
ductwork
longer
than
recommended.
3.
DO
NOT
use
a
plastic
or
nonĆmetal
duct
with
this
dryer.
4.
DO
NOT
use
a
duct
smaller
than
4
inches
in
diameter.
5.
DO
NOT
use
exhaust
hoods
with
magnetic
latches.
6.
DO
NOT
exhaust
the
dryer
into
a
chimney,
furnace
cold
air
duct,
attic,
crawl
space,
or
any
other
ductwork
used
for
venting.
7.
DO
NOT
install
a
flexible
duct
in
an
enclosed
wall,
ceiling
or
floor.
8.
DO
NOT
crush
or
kink
the
duct.
9.
Do
clean
and
inspect
the
exhaust
system
on
a
regular
basis;
at
least
once
a
year.
10.
The
exhaust
duct
must
terminate
in
a
manner
to
prevent
back
drafts
or
entry
of
birds
or
other
wildlife.
The
Bosch
dryer
must
be
vented
outdoors.
To
prevent
buildĆup
of
moisture
and
accumulation
of
lint
indoors,
as
well
as
to
maintain
maximum
drying
efficiency,
it
is
recommended
that
the
dryer
is
vented
outdoors.
Exhaust
air
outlet
on
the
dryer
The
dryer
is
delivered
with
an
exhaust
air
outlet
on
the
rear
of
the
appliance.
To
take
account
of
the
spatial
requirements
and
an
existing
exhaust
air
system,
the
following
connection
options
are
possible
for
the
exhaust
air
outlet:
-
on
right
side
of
the
appliance,
-
on
the
underside
of
the
appliance.