Brother International RJ-3050Ai P-touch Template Manual/ Command Reference - Page 43

Specify delimiter

Page 43 highlights

P-touch Template 2.0 Command Reference ^SS Specify delimiter ASCII: ^ S S n1 n2 Decimal: 94 83 83 nd1 nd2 Hexadecimal: 5E 53 53 nh1 nh2 data datad datah Parameters 0≤n1≤2 0≤n2≤9 00h≤datah≤FFh Description  The delimiter is used to indicate when to move to the next object in data that is being sent.  Specifies the text string for the delimiter. (n1*10)+n2: Length of the text string (between 1 and 20) data: Text string (The maximum number of characters that can be set is 20 characters (bytes).)  The default text string for the delimiter is "09h" (Tab code). A text string that will not appear in the print data should be specified.  This command is a dynamic command. Remarks  Invalid if more than 20 characters have been specified Example  To change the delimiter to "," (2Ch): Since the text string contains one character, n1=0 and n2=1. In addition, with the text string (datah) "," (2Ch), the command will be as follows. ^ S S 0 1 , (5Eh 53h 53h 30h 31h 2Ch) - 37 - 7. Control Command Details

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

P-touch Template 2.0 Command Reference
- 37 -
7. Control Command Details
^SS
Specify delimiter
ASCII:
^
S
S
n1
n2
data
Decimal:
94
83 83 nd1 nd2
datad
Hexadecimal: 5E
53 53 nh1 nh2
datah
Parameters
0
≤n1≤2
0≤n2≤9
00h≤datah≤FFh
Description
The delimiter is used to indicate when to move to the next object in data that is being sent.
Specifies the text string for the delimiter.
(n1*10)+n2: Length of the text string (between 1 and 20)
data:
Text string (The maximum number of characters that can be set is 20 characters (bytes).)
The default text strin
g for the delimiter is “09h” (T
ab code).
A text string that will not appear in the print data should be specified.
This command is a dynamic command.
Remarks
Invalid if more than 20 characters have been specified
Example
To
change the delimiter to “,” (
2Ch):
Since the text string contains one character, n1=0 and n2=1. In addition, with
the text string (datah) “,”
(2Ch), the command will be as follows.
^ S S 0 1 ,
(5Eh 53h 53h 30h 31h 2Ch)