Brother International RJ-3050Ai P-touch Template Manual/ Command Reference - Page 93
XESC iXm1 Retrieve character code set setting
View all Brother International RJ-3050Ai manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
P-touch Template 2.0 Command Reference ESC iXm1 Retrieve character code set setting ASCII: ESC i X m 1 n1 n2 Decimal: 27 105 88 109 49 nd1 nd2 Hexadecimal: 1B 69 58 6D 31 nh1 nh2 Parameters nh1: 00h (Fixed) nh2: 00h (Fixed) Description Retrieves the specified character code set. (For details on the character code sets, refer to "Appendix B: Character Code Tables".) 3-byte data is returned from the printer. [1]: 01h (Fixed) [2]: 00h (Fixed) [3]: Setting 00h: Brother standard 01h: Windows1250 (Eastern Europe) 02h: Windows1252 (Western Europe) 03h: ZPL II Emulation 04h: Japan The retrieved value is a value specified by a static command. Example When the character code set is the Brother standard: Code: ESC i X m 1 00h 00h (1Bh 69h 58h 6Dh 31h 00h 00h) Returned value: 01h 00h 00h - 87 - 7. Control Command Details