Brother International RJ-3050Ai P-touch Template Manual/ Command Reference - Page 78
XESC iXN2 NSpecify number of Numbering copies
View all Brother International RJ-3050Ai manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 78 highlights
P-touch Template 2.0 Command Reference ESC iXN2 Specify number of Numbering copies ASCII: ESC i X N 2 n1 n2 n3 n4 Decimal: 27 105 88 78 50 nd1 nd2 nd3 nd4 Hexadecimal: 1B 69 58 4E 32 nh1 nh2 nh3 nh4 Parameters nh1: 02h (Fixed) nh2: 00h (Fixed) 00h≤nh3≤FFh 00h≤nh4≤03h Description Specifies the number of copies to be printed with Numbering. nh3+(nh4*256): Number of Numbering copies (bytes) (1 to 999) The default number of copies printed with Numbering is 1. This command is a static command. Example To change the number of Numbering copies to 100: Since nh3=64h and nh4=00h, the command will be as follows. ESC i X N 2 02h 00h 64h 00h (1Bh 69h 58h 4Eh 32h 02h 00h 64h 00h) - 72 - 7. Control Command Details
P-touch Template 2.0 Command Reference
- 72 -
7. Control Command Details
ESC iXN2
Specify number of Numbering copies
ASCII:
ESC i
X
N
2
n1
n2
n3
n4
Decimal:
27
105 88
78
50 nd1 nd2 nd3
nd4
Hexadecimal: 1B
69
58
4E
32 nh1 nh2 nh3
nh4
Parameters
nh1: 02h (Fixed)
nh2: 00h (Fixed)
00h≤nh3≤FFh
00h≤nh4≤03h
Description
Specifies the number of copies to be printed with Numbering.
nh3+(nh4*256):
Number of Numbering copies (bytes) (1 to 999)
The default number of copies printed with Numbering is 1.
This command is a static command.
Example
To change the number of Numbering copies to 100:
Since nh3=64h and nh4=00h, the command will be as follows.
ESC i X N 2 02h 00h 64h 00h
(1Bh 69h 58h 4Eh 32h 02h 00h 64h 00h)