Page 52 highlights
P-touch Template 2.0 Command Reference ^QV Specify QR Code version ASCII: ^ Q V n1 n2 Decimal: 94 81 86 nd1 nd2 Hexadecimal: 5E 51 56 nh1 nh2 Parameters 0≤n1≤4 0≤n2≤9 Description Specifies the QR Code version. (n1*10)+n2: Version number (between 0 and 40) The default QR Code version is 0. This command becomes invalid if a value other than those that can be set (between 0 and 40) has been specified. This command is a dynamic command. Example To change the version to 10: Since n1=1 and n2=0, the command will be as follows. ^ Q V 1 0 (5Eh 51h 56h 31h 30h) - 46 - 7. Control Command Details
P-touch Template 2.0 Command Reference
- 46 -
7. Control Command Details
^QV
Specify QR Code version
ASCII:
^
Q
V
n1
n2
Decimal:
94
81 86 nd1 nd2
Hexadecimal: 5E
51 56 nh1 nh2
Parameters
0≤n1≤
4
0≤n2≤9
Description
Specifies the QR Code version.
(n1*10)
+
n2: Version number (between 0 and 40)
The default QR Code version is 0.
This command becomes invalid if a value other than those that can be set (between 0 and 40) has been
specified.
This command is a dynamic command.
Example
To change the version to 10:
Since n1=1 and n2=0, the command will be as follows.
^ Q V 1 0