switch the power on and adjust the mechanical end
View all Canon CINE-SERVO 50-1000mm T5.0-8.9 PL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
6 HOW TO ATTACH AND DETACH THE DRIVE UNIT 5 Set the zoom/focus operation change-over knobs of the drive unit to MANU. side, set the iris operation mode change-over switch to "M" side, and then turn the focus, zoom and iris ring manually and check gear engagement. 6 Verify that the gear of the drive unit is engaged with the gear of the lens and tighten the three fixing screws to the specified torque to fix the drive unit. * Tightening torque: 63 - 80 N•cm (6.4 - 8.2 kg•cm) 7 Mount the lens on the camera, connect the 12-pin cable, switch the power on and adjust the mechanical end automatically on the display. * For details on how to adjust the mechanical end automatically, refer to "6-3 AUTOMATIC ADJUSTMENT OF THE MECHANICAL END" on the next page. • If a drive unit fixing screw is damaged or lost, use a spare one. If all spare screws are used and additional ones are required, contact Canon Inc. or Canon distributers & sales representatives. E22