Canon LV-7105 Service Manual - Page 64
PC-Offset Adjustment, 4 PC Gain Adjustment
View all Canon LV-7105 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 64 highlights
Part 3: Adjustment 2.3 PC-Offset Adjustment 1. Receive the 16-step gray scale computer signal. 2. Set to COMPUTER mode. [R-Offset adjustment] 3. Connect an oscilloscope to test point "TP2211R" (+) and chassis ground (-). 4. Enter to the service mode, select item no. "275" and change data value to adjust the pedestal level and black level to be same level. [G-Offset adjustment] 5. Connect an oscilloscope to test point "TP2221G" (+) and chassis ground (-). 6. Select item no. "276" and change data value to adjust the pedestal level and black level to be same level. [B-Offset adjustment] 7. Connect an oscilloscope to test point "TP2231B" (+) and chassis ground (-). 8. Select item no. "277" and change data value to adjust the pedestal level and black level to be same level. Pedestal level = Black level Fig. 3-2 2.4 PC Gain Adjustment 1. Receive the 16-step gray scale computer signal. 2. Set to COMPUTER mode. [PC-R gain adjustment] 3. Connect an oscilloscope to test point "TP2211R" (+) and chassis ground (-). 4. Enter to the service mode, select item no. "30" and change data value to adjust "a" to be 1.05 ±0.01Vp-p. [PC-G gain adjustment] 5. Connect an oscilloscope to test point "TP2221G" (+) and chassis ground (-). 6. Select item no. "273" and change data value to adjust "a" to be 1.05 ±0.01Vp-p. [PC-B gain adjustment] 7. Connect an oscilloscope to test point "TP2231B " (+) and chassis ground (-). 8. Select item no. "274" and change data value to adjust "a" to be 1.05 ±0.01Vp-p. 3-8