Canon LV-7105 Service Manual - Page 65

Component Gain Adjustment

Page 65 highlights

Part 3: Adjustment (a) Pedestal level = Black level Fig. 3-3 2.5 Component Gain Adjustment 1. Receive the 16-step gray scale component video signal. 2. Set to VIDEO (Component) mode. [Component-R gain adjustment] 3. Connect an oscilloscope to test point "TP2211R" (+) and chassis ground (-). 4. Enter to the service mode, select item no. "30" and change data value to adjust "a" to be 1.05 ±0.01Vp-p. [Component-G gain adjustment] 5. Connect an oscilloscope to test point "TP2221G" (+) and chassis ground (-). 6. Select item no. "273" and change data value to adjust "a" to be 1.05 ±0.01Vp-p. [Component-B gain adjustment] 7. Connect an oscilloscope to test point "TP2231B " (+) and chassis ground (-). 8. Select item no. "274" and change data value to adjust "a" to be 1.05 ±0.01Vp-p. (a) Pedestal level = Black level Fig. 3-4 3-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

2.5 Component Gain Adjustment
1.
Receive the 16-step gray scale component video signal.
2.
Set to
VIDEO
(Component) mode.
[Component-R gain adjustment]
3.
Connect an oscilloscope to test point “TP2211R” (+) and chassis ground (-).
4.
Enter to the service mode, select item no. “30” and change data value to adjust “a” to
be 1.05 ±0.01Vp-p.
[Component-G gain adjustment]
5.
Connect an oscilloscope to test point “TP2221G” (+) and chassis ground (-).
6.
Select item no. “273” and change data value to adjust “a” to be 1.05 ±0.01Vp-p.
[Component-B gain adjustment]
7.
Connect an oscilloscope to test point “TP2231B ” (+) and chassis ground (-).
8.
Select item no. “274” and change data value to adjust “a” to be 1.05 ±0.01Vp-p.
Part 3: Adjustment
3-9
Pedestal level = Black level
(a)
Fig. 3-3
Fig. 3-4
Pedestal level = Black level
(a)