Canon LV-7105 Service Manual - Page 82
Fig. 4-1, On/off Button, Ac Input, Lamp Bst_sw., Lamp Power, 5v_sw., Sw902, Thermal Sw., Inter Lock
View all Canon LV-7105 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Part 4: Troubleshooting (Power-On: H) LAMP POWER 2 IC301 SYSTEM CONTROL (Power-On: H) LAMP BST_SW. 206 (Power-On: H) 5V_SW. 146 IIC BUS PSDA PSDA 17-18 KEY SW 16 POWER LED IC1803 14 READY LED KEY SWITCHES 15 TEMP LED 13 LAMP REP. LED ON/OFF BUTTON INDICATOR LAMP READY TEMP WARNING LAMP REPLACE Check that the LAMP indicator and READY indicator are lighting. If both of indicators are not lighting,check the primary side of the power supply circuit or S6V of standby power supply circuit. 19 FAN_DRIVE IC1804 (Power-On: H) 18 FAN CONT1 IC1806 IC1808 6 POWER_FAIL 2-5 KEY SW. (Abnormal: L) IC1851 POWER_FAIL 8 LAMP_ERR (Abnormal: H) Check that the 5V_SW signal at pin 11 of K3D is correct. H : Power ON Check that the POWER FAIL signal at pin 6 of IC1808 is correct. L : abnormal 5V_SW. POWER_FAIL FAN Check that the LAMP_BST_SW signal at pin 12 of K3D is correct. H : Power ON IC2882 IC2883 2 4 Is fuse (F601) blown? AC INPUT LAMP_BST_SW LAMP_ERR LAMP_SW F601 FUSE SW904 SW902 INTER LOCK THERMAL SW. SW. Check that the LAMP_POW signal at pin 2 of IC2882 is correct. Fig. 4-1 4-4