Canon LV-7105 Service Manual - Page 68

PC/AV-Video Adjustment-1, Presetting

Page 68 highlights

Part 3: Adjustment 2.10 PC/AV-Video Adjustment-1 Presetting 1. Input the 16-step gray scale video signal and computer signal. [PC/AV-video adjustment] 2. Connect an oscilloscope to test point "TP503G" (+) and chassis ground (-). 3. Enter to the service mode, select item no. "15" and change data value to adjust "b" to be 1.5 ±0.01Vp-p at each VIDEO and COMPUTER mode. 4. Select COMPUTER mode, select item no. "12" and change data value to adjust "a" to be 4.00 ±0.01Vp-p. 5. Select VIDEO mode, select item no. "12" and change data value to adjust "a" to be 4.00 ±0.01Vp-p. [R-video adjustment] 6. Connect an oscilloscope to test point "TP501R" (+) and chassis ground (-). 7. Enter to the service mode and select COMPUTER mode. 8. Select item no. "13" and change data value to adjust "a" to be 4.00 ±0.01Vp-p. 9. Select VIDEO mode and item no. "13" and change data value to adjust "a" to be 4.00 ±0.01Vp-p. [B-video adjustment] 10. Connect an oscilloscope to test point "TP505B" (+) and chassis ground (-). 11. Enter to the service mode and select COMPUTER mode. 12. Select item no. "14" and change data value to adjust "a" to be 4.00 ±0.01Vp-p. 13. Select VIDEO mode and item no. "14" and change data value to adjust "a" to be 4.00 ±0.01Vp-p. white level (b) white level (a) black level Fig. 3-8 3-12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

2.10 PC/AV-Video Adjustment-1
Presetting
1.
Input the 16-step gray scale video signal and computer signal.
[PC/AV-video adjustment]
2.
Connect an oscilloscope to test point “TP503G” (+) and chassis ground (-).
3.
Enter to the service mode, select item no. “15” and change data value to adjust “b” to
be 1.5 ±0.01Vp-p at each
VIDEO
and
COMPUTER
mode.
4. Select
COMPUTER
mode, select item no. “12” and change data value to adjust “a” to
be 4.00 ±0.01Vp-p.
5. Select
VIDEO
mode, select item no. “12” and change data value to adjust “a” to be
4.00 ±0.01Vp-p.
[R-video adjustment]
6.
Connect an oscilloscope to test point “TP501R” (+) and chassis ground (-).
7.
Enter to the service mode and select
COMPUTER
mode.
8.
Select item no. “13” and change data value to adjust “a” to be 4.00 ±0.01Vp-p.
9. Select
VIDEO
mode and item no. “13” and change data value to adjust “a” to be 4.00
±0.01Vp-p.
[B-video adjustment]
10.Connect an oscilloscope to test point “TP505B” (+) and chassis ground (-).
11.Enter to the service mode and select
COMPUTER
mode.
12.Select item no. “14” and change data value to adjust “a” to be 4.00 ±0.01Vp-p.
13.Select
VIDEO
mode and item no. “14” and change data value to adjust “a” to be 4.00
±0.01Vp-p.
Part 3: Adjustment
3-12
(a)
(b)
black level
white level
white level
Fig. 3-8