Canon LV-7105 Service Manual - Page 72

OPTICAL ADJUSTMENTS, 1 Contrast Adujstment

Page 72 highlights

Part 3: Adjustment 3. OPTICAL ADJUSTMENTS 3.1 Contrast Adujstment [Before adjustment] • Adjustment requires a 2.0mm hex wrench and a slot screwdriver. A • Remove cabinet top following to "Mechanical Disassemblies". • Input a 100% of black raster signal. CAUTION Do not disconnect the connectors on main and component boards otherwise the projector can not be turned on. Slot B Polarized glass mounting base Fig. 3-11 [R/G/B-contrast adujstment] 1. Project desired light component on the screen as follows. When adjusting the R-Contrast, project red light only. When adjusting the G-Contrast, project green light only. When adjusting the B-Contrast, project blue light only. 2. Loosen a screw A (Fig.3-11/3-12) on the polarized glass mounting base which you intend to adjust. 3. Adjust a slots B as shown in Fig.3-11 to obtain the darkest brightness on the screen by turning a slot screwdriver. 4. Tighten the screw A to fix the polarized glass mounting base. Repeat steps 1 to 4 for remaining polarized glasses. A B-Polarized Glass Mounting Base R-Polarized Glass Mounting Base A Main Board G-Polarized Glass A Mounting Base Fig. 3-12 3-16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134

Part 3: Adjustment
3-16
3. OPTICAL ADJUSTMENTS
3.1 Contrast Adujstment
[Before adjustment]
Adjustment requires a 2.0mm hex wrench and a
slot screwdriver.
Remove cabinet top following to “Mechanical
Disassemblies”.
Input a 100% of black raster signal.
[R/G/B-contrast adujstment]
1.
Project desired light component on the screen as follows.
When adjusting the R-Contrast, project red light only.
When adjusting the G-Contrast, project green light only.
When adjusting the B-Contrast, project blue light only.
2.
Loosen a screw
A
(Fig.3-11/3-12) on the polarized glass mounting base which you
intend to adjust.
3.
Adjust a slots
B
as shown in Fig.3-11 to obtain the darkest brightness on the screen
by turning a slot screwdriver.
4.
Tighten the screw
A
to fix the polarized glass mounting base.
Repeat steps 1 to 4 for remaining polarized glasses.
Do not disconnect the
connectors on main and
component boards
otherwise the projector can
not be turned on.
Slot B
Polarized glass
mounting base
A
Fig. 3-11
CAUTION
Fig. 3-12
B-Polarized Glass
Mounting Base
R-Polarized Glass
Mounting Base
G-Polarized Glass
Mounting Base
A
A
A
Main Board