Casio QT 6000 Programming Manual - Page 47
Programming void table, Programming system connection
![]() |
View all Casio QT 6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 47 highlights
4-1-10 Programming void table Operation: → 1.Machine Feature → 10.Void Table → Use Void Table VOID01 VOID02 VOID03 VOID04 VOID05 VOID06 Void Table 000000--- Descriptor and program value (refer the worksheet below) 000000 000000 000000 000000 000000 Worksheet for void table program Description Return stock value. Choice Yes = 0 No = 1 Program code : D1 4-1-11 Programming system connection Operation: → 1.Machine Feature → 11.System Connection System Connection * 1 MC #01 020101000000--- Descriptor and parameter (refer the worksheet below) 192163000001 * means my ID. 2 000000000000 000000000000 3 --- IP address 000000000000 000000000000 : 33 000000000000 000000000000 Worksheet for system connection program Description Terminal: Oneself = 02, Others = 01 Check tracking master/backup master (programmed value): Master = 01, Backup master = 02, Self master = 03, Satellite = 00 Check tracking master/backup master (current value): Master = 01, Backup master = 02, Self master = 03, Satellite = 00 Always "00000" Check tracking cluster No. (0 ~ 9) ("0" means no designation.) Choice Significant numbers Significant numbers Significant numbers Significant number Program code :: D12 D11 :: DD 10 9 :: D8 D7 ;;;;; DDDDD 6 5 4 3 2 : D1 QT-6000 Programming Manual P-47
![](/manual_guide/products/casio-qt-6000-programming-manual-11bf730/47.png)