Clifford Matrix RS III Owners Guide - Page 41

table of zones, interpreting zone diagnostics

Page 41 highlights

➜ table of zones A zone is represented by the LED flashes and remote control LCD icons used by the system to identify a particular type of input. Standard input assignments are listed in the following table. ZONE (Number of LED Flashes) DESCRIPTION LCD Icon 1 Instant trigger - trunk pinswitch 19 2 Shock trigger (-) - Full trigger and 17 Warn Away® of Sensor 1 3 Door switch trigger 9 4 Optional Sensor (-) - Full trigger and 18 Warn Away® 5 Ignition trigger 15 6 hood pinswitch 14 ➜ interpreting zone diagnostics Warn Away responses are not reported by the arming or disarming diagnostics. If you receive a Bypass notification when arming or a Tamper Alert notification when disarming, look at the LED or remote control LCD. Active or triggered zones will be indicated by a pattern of blinks by the LED or the remote control icon will indicate the triggered zone. Example If Zone 3 was active or triggered, the LED will blink three times with a two-second pause. Then it will blink three times again, 38 © 2002 directed electronics, inc.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53

38
© 2002 directed electronics, inc.
table of zones
A zone is represented by the LED flashes and remote control LCD
icons used by the system to identify a particular type of input.
Standard input assignments are listed in the following table.
ZONE
(Number of
LED Flashes)
DESCRIPTION
LCD Icon
1
Instant trigger - trunk pinswitch
19
2
Shock trigger (-) - Full trigger and
17
Warn Away
®
of Sensor 1
3
Door switch trigger
9
4
Optional Sensor (-) - Full trigger and
18
Warn Away
®
5
Ignition trigger
15
6
hood pinswitch
14
interpreting zone diagnostics
Warn Away responses are not reported by the arming or
disarming diagnostics. If you receive a Bypass notification when
arming or a Tamper Alert notification when disarming, look at
the LED or remote control LCD. Active or triggered zones will
be indicated by a pattern of blinks by the LED or the remote
control icon will indicate the triggered zone.
Example
If Zone 3 was active or triggered, the LED will blink three times
with a two-second pause. Then it will blink three times again,