Compaq AP200 Reference Guide - Page 145
for Windows NT. See, Comm Port 2 Address
UPC - 743172868534
View all Compaq AP200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 145 highlights
E-7 Power-On Self-Test Messages Continued Message Beeps* Probable Cause Recommended Action 1151-System Board 2S Comm Port 1 Address Assignment Conflict Both external and internal serial Run Computer Setup or ports are assigned to COM1. Windows NT utilities. 1152-System Board 2S Comm Port 2 Address Assignment Conflict Both external and internal serial Run Computer Setup or ports are assigned to COM2. Windows NT utilities. 1720-SMART Hard None Drive detects imminent failure Hard drive is about to fail. Back up contents and replace hard drive. 1771-Primary Disk 2S Port Address Assignment Conflict Internal and external hard drive Run Computer Setup or controllers are both assigned to Windows NT utilities. the primary address. 1772-Secondary Disk 2S Port Address Assignment Conflict Internal and external hard drive Run Computer Setup or controllers are both assigned to Windows NT utilities. the secondary address. 1780-Disk 0 Failure None Hard drive/format error. Run Compaq Diagnostics for Windows NT. See Chapter 2, "Software." 1781-Disk 1 Failure None Hard drive/format error. * L = Long, S = Short Run Compaq Diagnostics for Windows NT. See Chapter 2, "Software." Continued Compaq Professional Workstation AP200 Reference Guide