Compaq ProLiant 4500 ProLiant Server Troubleshooting Guide - Page 243
XC-63, Run Array Diagnostic
View all Compaq ProLiant 4500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 243 highlights
POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1785-Slot X Drive Array not Configured (followed by one of the following): None Drive array configuration not detected. (1) Run Compaq Array Configuration Utility (2) No drives detected (3) Drive positions appear to have changed - Run Drive Array Advanced Diagnostics if previous positions are unknown. Then turn system power OFF and move drives to their original positions. (4) Configuration information indicates drive positions beyond the capability of this controller. This may be due to drive movement from a controller that supports more drives than the current controller. (5) Configuration information indicates drives were configured on a controller with a newer firmware version. Action 1. Run the Array Configuration Utility. 2. Turn off system and check SCSI cable connections to be sure that drives are connected properly. 3. Run Array Diagnostic Utility if previous positions are unknown. Then, turn system power off and move drives to their original positions. 4. To avoid data loss, reconnect drives to the original controller or upgrade the controller firmware to the version on the original controller (or higher) using Option ROMPaq. continued HP Servers Troubleshooting Guide C-63