Compaq ProLiant 6400R Compaq ProLiant 6400R Servers - Page 107
SCSI Port x Drive
![]() |
View all Compaq ProLiant 6400R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 107 highlights
3-40 Compaq ProLiant 6400R Maintenance and Service Guide Table 3-18 ADU Diagnostic Messages continued Message Description Loose cable detected logical drives may be marked FAILED until corrected ADU found loose cable. If logical drives are marked FAILED, they will be unusable until the problem is corrected. Loose cable detected logical drives may be marked FAILED until corrected Controller unable to communicate with one or more physical drives, probably because of a cabling problem. Logical drives may be in a FAILED state until the condition is corrected, preventing access to data on the controller. Mirror data miscompare Data was found at reinitialization in the posted write memory. However, the mirror data compare test failed, resulting in data marked as invalid. Data loss is possible. No configuration for accelerator board The array accelerator board has not been configured. NVRAM configuration present, controller not detected EISA nonvolatile RAM has a configuration for an array controller, but there is no board in this slot. Either a board has been removed from the system, or a board has been placed in the wrong slot. RIS copies between drives do not match Drives on controller contain copies of RIS that do not match. SCSI Port x Drive ID x has exceeded threshold(s) Monitor and performance threshold for this drive has been violated. SCSI Port x Drive ID x is not stamped for monitoring Drive has not been stamped with monitor and performance features. SCSI Port x Drive ID x RIS copy mismatch Copies of RIS on drive do not match. Recommended Action Turn off the system. Check cables for tight connection to logical drives. Restart the system. If the same message recurs, cables may be bad. Check all controller and drive cable connections. Replace the array accelerator board. If the array accelerator board is present, run the ACU)to configure the board. Place the array controller in the proper slot, or run the System Configuration Utility to reconfigure nonvolatile RAM to reflect the removal or new position. Upgrade ADU to the most recent version. Check for the particular threshold that has been violated. Run the ACU. Changing the configuration and saving should cause ACU to stamp the drive with monitor and performance features. To do this without destroying the current configuration, change the array accelerator size, and save the configuration. Change the array accelerator back to the original size, and save again. Drive may need to be replaced. Check for other errors. continued
![](/manual_guide/products/compaq-6400r-compaq-proliant-6400r-servers-016a1de/107.png)