Craftsman 16781 Owners Manual - Page 14

Make sure the On/Auto/Off

Page 14 highlights

Check Valve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank. When the air compressor reaches "cut-out" pressure, the check valve "closes", allowing air pressure to remain inside the air tank. Check Valve 3. Depress the red reset button on the motor. 4. Place the On/Auto/Off lever in the "On/Auto" postion to restart the motor. Air Intake Filter (not shown): This filter is designed to clean air coming into the pump. This filter must always be clean and ventilation openings free from obstructions. See "Maintenance". Pressure Release Valve: The pressure release valve located on the side of the pressure switch, is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches "cut-out" pressure or is shut off. The pressure release valve allows the motor to restart freely. When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running or after the unit reaches "cut-out" pressure. Motor Overload Protector: This motor has a manual thermal overload protector. If the motor overheats for any reason, the overload protector will shut off the motor. The motor must be allowed to cool down before restarting. To restart: 1. Place the On/ Auto/Off lever in the "Off" position. 2. Allow the motor to cool. HOW TO USE YOUR UNiT How to Stop: 1 Set the On/Auto/Off lever to "Off" Before Starting _Do unitnuonttilopyeorautereathdis and understand this instruction manual for safety, operation and maintenance instructions. Break-in Procedure _Risk DamaogfeP. roSpeerirotyus damage may result if the following break-in instructions are not closely followed. This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. 1. Make sure the On/Auto/Off lever is in the "Off" position. 2. Check oil level in pump. See "Oil" paragraph in the Maintenance section for instructions. 3. Recheck all wiring. Make sure wires are secure at all terminals connections. Make sure all con- tacts move freely and are not obstructed. 4. Open the globe valve fully to permit air to escape and prevent air pressure build up in the air tank during the break-in period. 5. Move the On/Auto/Off lever to "On/Auto" position. The compressor will start. 6. Run the compressor for 20 minutes. Make sure the globe valve is open and there is minimal air pressure build-up in tank. 1000002023 14 ENG

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

Check
Valve:
When the air compres-
sor is operating,
the check
valve is
"open", allowing
compressed
air to
enter the air tank.
When the air com-
pressor reaches "cut-out"
pressure,
the check valve "closes",
allowing
air
pressure to remain inside the air tank.
Check
Valve
Pressure
Release
Valve:
The pres-
sure release valve located
on the side
of the pressure switch,
is designed to
automatically
release compressed
air
from the compressor
head and the
outlet tube when the air compressor
reaches "cut-out"
pressure or is shut
off. The pressure release valve allows
the motor to restart freely. When the
motor stops
running, air will be heard
escaping
from this valve for a few sec-
onds.
No air should be heard leaking
when the motor is running or after the
unit reaches "cut-out"
pressure.
Motor
Overload
Protector:
This
motor
has a manual thermal
overload
protector.
If the motor overheats
for
any reason, the overload
protector
will shut
off the motor.
The motor
must be allowed
to cool down
before
restarting.
To restart:
1.
Place the On/
Auto/Off
lever in the
"Off" posi-
tion.
2.
Allow the
motor to
cool.
3.
Depress the red reset button on
the motor.
4.
Place the On/Auto/Off
lever in the
"On/Auto"
postion
to restart the
motor.
Air Intake
Filter
(not shown):
This
filter is designed
to clean air com-
ing into the pump. This filter must
always
be clean
and ventilation
openings
free from
obstructions.
See
"Maintenance".
HOW
TO
USE
YOUR
UNiT
How
to Stop:
1
Set the On/Auto/Off
lever to "Off"
Before
Starting
_Do
not
operate
this
unit
until
you read
and understand
this
instruction
manual
for safety,
operation
and
maintenance
instructions.
Break-in
Procedure
_Risk
of Property
Damage. Serious
damage
may result if the following
break-in
instructions
are not
closely followed.
This procedure
is required before
the
air compressor
is put into service
and
when the check
valve or a complete
compressor
pump
has been replaced.
1.
Make sure the On/Auto/Off
lever
is in the "Off" position.
2.
Check oil level in pump. See "Oil"
paragraph
in the Maintenance
section for instructions.
3.
Recheck all wiring. Make sure
wires are secure at all terminals
connections.
Make sure all con-
tacts move freely and are not
obstructed.
4.
Open the globe valve fully to per-
mit air to escape and prevent air
pressure
build up in the air tank
during the break-in
period.
5.
Move the On/Auto/Off
lever to
"On/Auto"
position.
The compres-
sor will start.
6.
Run the compressor
for 20 min-
utes. Make sure the globe valve
is open and there is minimal air
pressure
build-up
in tank.
1000002023
14 ENG