D-Link DGS-3630 User Manual - Page 52

RMON Alarm Settings, Management > RMON > RMON Alarm Settings

Page 52 highlights

DGS-3630 Series Layer 3 Stackable Managed Switch Web UI Reference Guide After clicking the Show Detail button, the following window will appear. Figure 4-21 RMON History Settings (Show Detail) Window Click the Back button to return to the previous window. RMON Alarm Settings This window is used to display and configure alarm entries to monitor an interface. To view the following window, click Management > RMON > RMON Alarm Settings, as shown below: Figure 4-22 RMON Alarm Settings Window The fields that can be configured are described below: Parameter Index Interval Variable Type Rising Threshold Falling Threshold Rising Event Number Falling Event Number Owner Description Enter the alarm index. The range is from 1 to 65535. Enter the interval in seconds for the sampling of the variable and checking against the threshold. The valid range is from 1 to 2147483648 seconds. Enter the object identifier of the variable to be sampled. Select the monitoring type. Options to choose from are Absolute and Delta. Enter the rising threshold value between 0 and 2147483647. Enter the falling threshold value between 0 and 2147483647. Enter the index of the event entry that is used to notify the rising threshold crossing event. The valid range is from 1 to 65535. If not specified, no action is taken while crossing the ringing threshold. Enter the index of the event entry that is used to notify the falling threshold crossing event. The valid range is from 1 to 65535. If not specified, no action is taken while crossing the falling threshold. Enter the owner string up to 127 characters. Click the Add button to add a new entry based on the information entered. Click the Delete button to remove the specified entry. 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184

DGS-3630 Series Layer 3 Stackable Managed Switch Web UI Reference Guide
45
After clicking the
Show Detail
button, the following window will appear.
Figure 4-21 RMON History Settings (Show Detail) Window
Click the
Back
button to return to the previous window.
RMON Alarm Settings
This window is used to display and configure alarm entries to monitor an interface.
To view the following window, click
Management > RMON > RMON Alarm Settings
, as shown below:
Figure 4-22 RMON Alarm Settings Window
The fields that can be configured are described below:
Parameter
Description
Index
Enter the alarm index. The range is from 1 to 65535.
Interval
Enter the interval in seconds for the sampling of the variable and checking
against the threshold. The valid range is from 1 to 2147483648 seconds.
Variable
Enter the object identifier of the variable to be sampled.
Type
Select the monitoring type. Options to choose from are
Absolute
and
Delta
.
Rising Threshold
Enter the rising threshold value between 0 and 2147483647.
Falling Threshold
Enter the falling threshold value between 0 and 2147483647.
Rising Event Number
Enter the index of the event entry that is used to notify the rising threshold
crossing event. The valid range is from 1 to 65535. If not specified, no action is
taken while crossing the ringing threshold.
Falling Event Number
Enter the index of the event entry that is used to notify the falling threshold
crossing event. The valid range is from 1 to 65535. If not specified, no action is
taken while crossing the falling threshold.
Owner
Enter the owner string up to 127 characters.
Click the
Add
button to add a new entry based on the information entered.
Click the
Delete
button to remove the specified entry.