DeLonghi PAC WE125 Owner Manual - Page 20

Troubleshooting

Page 20 highlights

TROUBLESHOOTING problem CAUSE SOLUTION The air conditioner does not come on The air conditioner works for a short time only The air conditioner works, but does not cool the room • there is no current • it is not plugged into the outlet • the internal safety device has tripped • there are bends or kinks in the air exhaust hose • something is preventing the air from being discharged • windows, doors and/or curtains open • there are heat sources in the room (oven, hairdryer, etc) • the air exhaust hose is detached from the appliance During operation, there is an unpleasant smell in the room • dust filters clogged • the technical specification of the appliance is not adequate for the room in which it is located. • dust filter and (when present) electrostatic filter clogged • wait • plug into the outlet • call the Service Center • position the air hose correctly, keeping it as short and free of curves as possible to avoid bottlenecks. • check and remove any obstacles obstructing air discharge • close doors, windows and curtains, bearing in mind the "tips for correct use" given above • eliminate the heat sources • fit the air exhaust hose in the housing at the back of the appliance (fig. 1). • clean or replace the filters as described above • clean the filters as described above The air conditioner does not operate for about three minutes after restarting it • the internal compressor safety device prevents the appliance from being restarted until three minutes have elapsed since it was last turned off. • wait. This delay is part of normal operation. The symbol and one of the following messages LT / HL/Cf/PF / FI appears on the appliance display: • The appliance has a self diagnosis system to identify a number of malfunctions. • See the SELF-DIAGNOSIS chapter. 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21

20
PROBLEM
CAUSE
SOLUTION
The air conditioner
does not come on
there is no current
it is not plugged into the outlet
the internal safety device has tripped
wait
plug into the outlet
call the Service Center
The air conditioner
works for a short time
only
there are bends or kinks in the air
exhaust hose
something is preventing the air from
being discharged
position the air hose correctly, keeping
it as short and free of curves as possible
to avoid bottlenecks.
check and remove any obstacles
obstructing air discharge
The air conditioner
works, but does not
cool the room
windows, doors and/or curtains open
there are heat sources in the room
(oven, hairdryer, etc)
the air exhaust hose is detached from
the appliance
dust filters clogged
the technical specification of the
appliance is not adequate for the room
in which it is located.
close doors, windows and curtains,
bearing in mind the “TIPS FOR
CORRECT USE” given above
eliminate the heat sources
fit the air exhaust hose in the housing at
the back of the appliance (fig. 1).
clean or replace the filters as described
above
During operation, there
is an unpleasant smell
in the room
dust filter and (when present)
electrostatic filter clogged
clean the filters as described above
The air conditioner
does not operate for
about three minutes
after restarting it
the internal compressor safety device
prevents the appliance from being
restarted until three minutes have
elapsed since it was last turned off.
wait. This delay is part of normal
operation.
The symbol
and
one of the following
messages
LT / HL/Cf/PF / FI
appears on the
appliance display:
The appliance has a self diagnosis
system to identify a number of
malfunctions.
See the SELF-DIAGNOSIS chapter.