DeLonghi PAC WE125 Owner Manual - Page 6

Air-conditioning with installation

Page 6 highlights

Keep the air hose as short and free of curves as possible to avoid bottlenecks. Air-conditioning with installation If required, your appliance can be installed semipermanently (Fig. 6). Proceed as follows: • Drill a 5.27 inch (134 mm) dia. hole in an outside wall or through a window pane, respecting the heights shown in fig. 7. 6 9 in the wooden kickboard of a French window 10 12 inch 30 cm 12 inch 30 cm • Fit the flange accessory (S) provided in the hole following the indications in figs. 8, 9 and 10. 7 MAX 39 inch MIN 14 inch 8 in the wall: you are recommended to insulate the section of wall using suitable insulation. • Fit the air exhaust hose (K) in the housing at the back of the appliance (fig. 1). • Fit the end of the hose to the flange (S). When the hose is not fitted, the hole can be closed with the flange cap. • Remove the cap at the back of the appliance (G) and replace with the drain hose plus cap (U) as shown in figure 11. This enables the condensate to be drained more easily at the end of the season. See the section: "END OF SEASON OPERATIONS". Keep the air hose as short and free of curves as possible to avoid bottlenecks. When installing the air conditioner semipermanently, you should leave a door slightly open, as little as 0.5 inch (1 cm), to guarantee correct ventilation. 11 5 inch 134 in the window pane 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21

6
Keep the air hose as short and free of cur-
ves as possible to avoid bottlenecks.
Air-conditioning with installation
If required, your appliance can be installed semi-
permanently (Fig. 6).
Proceed as follows:
Drill a 5.27 inch (134 mm) dia. hole in an
outside wall or through a window pane, re-
specting the heights shown in fig. 7.
Fit the flange accessory (S) provided in the
hole following the indications in figs. 8, 9 and
10.
12 inch
30 cm
30 cm
12 inch
MAX
39 inch
MIN
14 inch
in the window pane
in the wooden kickboard of a French window
in the wall: you are recommended to insulate
the section of wall using suitable insulation.
Fit the air exhaust hose (K) in the housing at
the back of the appliance (fig. 1).
Fit the end of the hose to the flange (S).
When the hose is not fitted, the hole can be
closed with the flange cap.
Remove the cap at the back of the appliance
(G) and replace with the drain hose plus cap
(U) as shown in figure 11. This enables the
condensate to be drained more easily at the
end of the season. See the section: “END OF
SEASON OPERATIONS”.
Keep the air hose as short and free of cur-
ves as possible to avoid bottlenecks.
When installing the air conditioner semi-
permanently, you should leave a door slightly
open, as little as 0.5 inch (1 cm), to guarantee
correct ventilation.
6
8
9
10
7
134
5 inch
11