Supported Products and FOS Interoperability Brocade 6510 Brocade 6505 Brocade 6520 48000 with FA4-18 blade(s), Brocade 7600 Secure Fabric OS (on any model) Mi10k, M6140, ED-6064, ES-3232, ES-4300, ES-4400, ES-4500, ES4700 (McDATA Fabric Mode and Open Fabric Mode) 1 McDATA ED-5000 32-port FC director FOS v7.0 or later FOS v7.0.1 or later FOS v7.1 or later V6.2.2 or later 6 Not Supported Direct E_Port connections are not supported - must use FCR running pre-FOS v7.1. M-EOS v9.9.5 or later Not Supported Multi-Protocol Router Interoperability Brocade 7420 Brocade 7500 and FR4-18i blade McDATA SANRouters 1620 and 2640 Not supported V6.2.2 and higher 4 6 8 Not Supported NOS (VDX Platform) Interoperability Brocade VDX6710, VDX6720, VDX6730 Brocade VDX8770 NOS v2.1.1 or later7 NOS 3.0 or later Table Notes: 1 When routing to an M-EOS edge fabric using frame redirection, the M-EOS fabric must have a FOS-based product in order to configure the frame redirection zone information in the edge fabric. 2 When directly attached to a Host or Target that is part of an encryption flow. 3 These platforms may not be directly attached to hosts or targets for encryption flows. 4 McDATA 1620 and 2640 SANRouters should not be used with FOS-based routing (FCR) for connections to the same edge fabric. 5 FA4-18 is not supported in a DCX/DCX-4S that is running FOS v7.0 or later 6 If operating with FOS v6.2.2e or earlier, Adaptive Networking QoS must be disabled when connecting to 16G FC platform. Otherwise, ISL will segment. 7 Connectivity to FC SAN is established via VDX6730 connected to FCR running FOS v7.0.1 or later. FCR platforms supported include 5100, VA-40FC, 5300, 7800, DCX, DCX-4S, DCX 8510-8, DCX 8510-4, 6510, 6520 (requires FOS v7.1 or later). For higher FCR backbone scalability (refer to separate "Brocade SAN Scalability Guidelines" documentation for details), please use 5300, 6520, DCX, DCX-4S, DCX 8510-8, DCX 8510-4. 8 FR4-18i and FC10-6 are not supported on DCX/DCX-4S on FOS v7.1 or later. Fabric OS v7.1.0a Release Notes v1.0 Page 25 of 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

Fabric OS v7.1.0a Release Notes v1.0
Page 25 of 41
Supported Products and FOS Interoperability
Brocade 6510
FOS v7.0 or later
Brocade 6505
FOS v7.0.1 or later
Brocade 6520
FOS v7.1 or later
48000 with FA4-18 blade(s), Brocade 7600
V6.2.2 or later
6
Secure Fabric OS (on any model)
Not Supported
Mi10k, M6140, ED-6064, ES-3232, ES-4300, ES-4400, ES-4500, ES-
4700 (McDATA Fabric Mode and Open Fabric Mode)
1
Direct E_Port connections are not
supported
must use FCR
running
pre-FOS v7.1.
M-EOS v9.9.5 or later
McDATA ED-5000 32-port FC director
Not Supported
Multi-Protocol Router Interoperability
Brocade 7420
Not supported
Brocade 7500 and FR4-18i blade
V6.2.2 and higher
4 6 8
McDATA SANRouters 1620 and 2640
Not Supported
NOS (VDX Platform) Interoperability
Brocade VDX6710, VDX6720, VDX6730
NOS v2.1.1 or later
7
Brocade VDX8770
NOS 3.0 or later
Table Notes:
1
When routing to an M-EOS edge fabric using frame redirection, the M-EOS fabric must have a FOS-based product in
order to configure the frame redirection zone information in the edge fabric.
2
When directly attached to a Host or Target that is part of an encryption flow.
3
These platforms may not be directly attached to hosts or targets for encryption flows.
4
McDATA 1620 and 2640 SANRouters should not be used with
FOS-based routing (FCR) for connections to the same
edge fabric.
5
FA4-18 is not supported in a DCX/DCX-4S that is running FOS v7.0 or later
6
If operating with
FOS v6.2.2e or earlier
,
Adaptive Networking QoS must be disabled when connecting to 16G FC
platform. Otherwise, ISL will segment.
7
Connectivity to FC SAN is established via VDX6730 connected to FCR running FOS v7.0.1 or later. FCR platforms
supported include 5100, VA-40FC, 5300, 7800, DCX, DCX-4S, DCX 8510-8, DCX 8510-4, 6510, 6520 (requires FOS
v7.1 or later). For higher FCR backbone scalability
(refer to separate “
Brocade SAN Scalability Guidelines
documentation for details), please use 5300, 6520, DCX, DCX-4S, DCX 8510-8, DCX 8510-4.
8
FR4-18i and FC10-6 are not supported on DCX/DCX-4S on FOS v7.1 or later.