Dell Brocade 6520 Release Notes v1.0 - Page 30

Fabric OS v7.1.0a Release Notes v1.0, of 41, Notes

Page 30 highlights

Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8 (For specific calculation of power draw with different blade combinations, please refer to Appendix A: Power Specifications in the 8510-8 Backbone Hardware Reference Manual) Configured Number of Ports Blades Type of Blade DCX 8510-8 @110 VAC (Redundant configurations) DCX 8510-8 @200-240 VAC (Redundant configurations) Comments 336 8Gb ports + QSFP ICLs 384 16Gb ports + QSFP ICLs FC8-48E (Maximum of seven FC8-48E blades, with one empty port blade slot) FC16-32, FC16-48 Port Blade Port Blade 4 Power Supplies 2 Power Supplies Not Supported 4 Power Supplies 384 8Gb ports + QSFP ICLs FC8-32E, FC8-48E Port Blade Not Supported 4 Power Supplies Any combination of 8Gb or 16Gb ports and intelligent blades with QSFP ICLs FC16-32, FC16-48, FC8-64, FC8-32E, FC8-48E, FS8-18, FX8-24 Intelligent Blade /Combination Not Supported 4 Power Supplies 200-240VAC: 1+1 Power Supplies 110VAC: 2+21 Power Supplies Max 7 FC8-48E port blades 200-240VAC: For DCX 8510-8, four (2+2)1 220V AC Power Supplies are required 200-240VAC: For DCX 8510-8, four (2+2)1 220V AC Power Supplies are required For DCX 8510-8, four (2+2)1 220V AC Power Supplies are required when any special purpose blade are installed Table 4 Power Supply Requirements for DCX 8510-8 Notes: 1. When 2+2 power supply combination is used, the users are advised to configure the Fabric Watch setting for switch marginal state to be two power supplies. Users can use the CLI switchstatuspolicyset to configure this value if the current value is set to zero. In FOS v7.0.x, the default setting for the marginal state due to missing power supplies is incorrectly set to zero (Defect 000349586), which will prevent Fabric Watch from generating notifications when the switch enters the marginal state due to missing power supplies Fabric OS v7.1.0a Release Notes v1.0 Page 30 of 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

Fabric OS v7.1.0a Release Notes v1.0
Page 30 of 41
Typical Power Supply Requirements Guidelines for Blades in DCX 8510-8
(For specific calculation of power draw with different blade combinations,
please refer to Appendix A: Power Specifications
in the 8510-8 Backbone Hardware Reference Manual)
Configured
Number of Ports
Blades
Type of Blade
DCX 8510-8
@110 VAC
(Redundant
configurations)
DCX 8510-8
@200-240 VAC
(Redundant
configurations)
Comments
336 8Gb ports +
QSFP ICLs
FC8-48E
(Maximum of
seven FC8-48E
blades, with one
empty port blade
slot)
Port Blade
4 Power Supplies
2 Power
Supplies
200-240VAC: 1+1
Power Supplies
110VAC: 2+2
1
Power Supplies
Max 7 FC8-48E port
blades
384 16Gb ports +
QSFP ICLs
FC16-32, FC16-48
Port Blade
Not Supported
4 Power
Supplies
200-240VAC:
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
384 8Gb ports +
QSFP ICLs
FC8-32E, FC8-48E
Port Blade
Not Supported
4 Power
Supplies
200-240VAC:
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
Any combination
of 8Gb or 16Gb
ports and
intelligent blades
with
QSFP ICLs
FC16-32, FC16-48,
FC8-64, FC8-32E,
FC8-48E, FS8-18,
FX8-24
Intelligent
Blade
/Combination
Not Supported
4 Power
Supplies
For DCX 8510-8, four
(2+2)
1
220V AC Power
Supplies are required
when any special
purpose blade are
installed
Table 4 Power Supply Requirements for DCX 8510-8
Notes:
1.
When 2+2 power supply combination is used, the users are advised to configure the Fabric Watch setting for
switch marginal state to be two power supplies. Users can use the CLI switchstatuspolicyset to configure this
value if the current value is set to zero. In FOS v7.0.x, the default setting for the marginal state due to missing
power supplies is incorrectly set to zero (Defect 000349586), which will prevent Fabric Watch from generating
notifications when the switch enters the marginal state due to missing power supplies