Dell Brocade 6520 Release Notes v1.0 - Page 28

Power Supply Requirements for Blades in DCX/DCX-4S, Blades, Type of Blade, DCX/DCX-4S, Comments,

Page 28 highlights

Power Supply Requirements for Blades in DCX/DCX-4S Blades DCX/DCX-4S Type of Blade @110 VAC (Redundant configurations) DCX/DCX-4S @200-240 VAC (Redundant configurations) FC10-61, FC816, FC8-32, FC 8-48, FC864 FR4-18i1 FS8-18, FX8-24, FCOE10-24 Port Blade Intelligent Blade Intelligent Blade 2 Power Supplies Not Supported Not Supported 2 Power Supplies 2 Power Supplies DCX: 2 or 4 Power Supplies DCX-4S: 2 Power Supplies Comments  Distribute the Power Supplies evenly to 2 different AC connections for redundancy.  For DCX with three or more FS8-18 Blades, (2+2) 220VAC Power Supplies are required for redundancy.  For DCX with one or two FS8-18 Blades, (2) 220VAC Power Supplies are required for redundancy.  For DCX-4S, (2) 220VAC Power Supplies provide redundant configuration with any supported number of FS8-18 Blades.  For both DCX and DCX-4S with FX8-24 blades, (1+1) 220VAC Power Supplies are required for redundancy. Table 3 Power Supply Requirements for DCX and DCX-4S 1. Note that FC10-6 and FR4-18i are not supported with FOS v7.1 or later Fabric OS v7.1.0a Release Notes v1.0 Page 28 of 41

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

Fabric OS v7.1.0a Release Notes v1.0
Page 28 of 41
Power Supply Requirements for Blades in DCX/DCX-4S
Blades
Type of Blade
DCX/DCX-4S
@110 VAC
(Redundant
configurations)
DCX/DCX-4S
@200-240 VAC
(Redundant
configurations)
Comments
FC10-6
1
, FC8-
16, FC8-32,
FC 8-48, FC8-
64
Port Blade
2 Power
Supplies
2 Power Supplies
Distribute the Power Supplies
evenly to 2 different AC
connections for redundancy.
FR4-18i
1
Intelligent
Blade
Not Supported
2 Power Supplies
FS8-18,
FX8-24,
FCOE10-24
Intelligent
Blade
Not Supported
DCX: 2 or 4 Power
Supplies
DCX-4S: 2 Power
Supplies
For DCX with three or more
FS8-18 Blades, (2+2)
220VAC Power Supplies are
required for redundancy.
For DCX with one or two
FS8-18 Blades, (2) 220VAC
Power Supplies are required
for redundancy.
For DCX-4S, (2) 220VAC
Power Supplies provide
redundant configuration
with any supported number
of FS8-18 Blades.
For both DCX and DCX-4S
with FX8-24 blades, (1+1)
220VAC Power Supplies are
required for redundancy.
Table 3 Power Supply Requirements for DCX and DCX-4S
1. Note that FC10-6 and FR4-18i are not supported with FOS v7.1 or later