Dell Equallogic PS6010 Storage Arrays - Hardware Owners Manual - Page 14

Warning LED Status Conditions, Table 1-2: Operations Panel Descriptions Continued

Page 14 highlights

PS6010 Hardware Maintenance Basic Array Information Table 1-2: Operations Panel Descriptions (Continued) Callout Item Color Serial number label N/A Description This label contains the serial number for your array. If you contact your PS Series support provider, you may need to provide this number. Warning LED Status Conditions When the Warning LED is flashing orange, one or more of the following has occurred: • RAID set is degraded but still functioning. • RAID set (volume level) has lost blocks. • Component temperature is near a limit. • Fan failed or fan RPMs exceed limit. • Power supply is not installed or has no power. • Cache battery has less than 72 hours of charge. • Only one control module installed or control module has failed over. • Control module has insufficient RAM. • Syncing active and secondary control modules. • No communication between control modules. • Installed spare disk drive does not have enough capacity to replace a disk drive in a RAID set. • A non-critical hardware component failed. • Real-time clock battery is low. Critical LED Status Conditions When the Critical LED is flashing orange, one or more of the following has occurred: • RAID is not functioning. • Lost block table is full. 1-4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57

PS6010 Hardware Maintenance
Basic Array Information
1–4
Warning LED Status Conditions
When the Warning LED is flashing orange, one or more of the following has
occurred:
RAID set is degraded but still functioning.
RAID set (volume level) has lost blocks.
Component temperature is near a limit.
Fan failed or fan RPMs exceed limit.
Power supply is not installed or has no power.
Cache battery has less than 72 hours of charge.
Only one control module installed or control module has failed over.
Control module has insufficient RAM.
Syncing active and secondary control modules.
No communication between control modules.
Installed spare disk drive does not have enough capacity to replace a disk
drive in a RAID set.
A non-critical hardware component failed.
Real-time clock battery is low.
Critical LED Status Conditions
When the Critical LED is flashing orange, one or more of the following has
occurred:
RAID is not functioning.
Lost block table is full.
Serial number label
N/A
This label contains the serial number
for your array. If you contact your
PS Series support provider, you may
need to provide this number.
Table 1-2: Operations Panel Descriptions (Continued)
Callout
Item
Color
Description