Dell Equallogic PS6010 Storage Arrays - Hardware Owners Manual - Page 14
Warning LED Status Conditions, Table 1-2: Operations Panel Descriptions Continued
View all Dell Equallogic PS6010 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
PS6010 Hardware Maintenance Basic Array Information Table 1-2: Operations Panel Descriptions (Continued) Callout Item Color Serial number label N/A Description This label contains the serial number for your array. If you contact your PS Series support provider, you may need to provide this number. Warning LED Status Conditions When the Warning LED is flashing orange, one or more of the following has occurred: • RAID set is degraded but still functioning. • RAID set (volume level) has lost blocks. • Component temperature is near a limit. • Fan failed or fan RPMs exceed limit. • Power supply is not installed or has no power. • Cache battery has less than 72 hours of charge. • Only one control module installed or control module has failed over. • Control module has insufficient RAM. • Syncing active and secondary control modules. • No communication between control modules. • Installed spare disk drive does not have enough capacity to replace a disk drive in a RAID set. • A non-critical hardware component failed. • Real-time clock battery is low. Critical LED Status Conditions When the Critical LED is flashing orange, one or more of the following has occurred: • RAID is not functioning. • Lost block table is full. 1-4