Dell N3200-ON Open Networking Hardware Diagnostic Guide July 2022 - Page 40

Output, list output, List the LEDs

Page 40 highlights

(or) ledtool -s -Y Test using config file:= ledtool --test [--config=] (or) ledtool -t [-f ] Test LED manually ledtool --test --manual (or) ledtool -t -m Set led pre and post seetings := ledtool --set --led= --mode= [normal] (or) ledtool -s -D -M Syntax: ledtool -h, --h Show the help text -l, --list List the LEDs -g, --get Get operation -s, --set Set operation -t, --test Test using the pre-programmed configuration or use supplied config -D, --led= LED -I, --iteration= Iteration command execution -S, --instance=, Instance -T, --state=, State of the LED -V, --val=, Value to be set -f, --config=, To specify the location of the config file e.g. /etc/dn/diag/ -U, --cpu_ctrl, Set CPU control -Y, --fpga_ctrl, Set FPGA control -M, --mode, Set CPLD Mode -m, --manual, Manual LED test Output list output root@dellemc-diag-os:~# ledtool --list Fan : options off solid-amber solid-green flashing-amber System : options flashing-green solid-green solid-amber flashing-amber Beacon : options off flashing-blue Power : options off solid-amber solid-green flashing-amber Stacking : options solid-green off Stack-val : options 0-F 7-digit : options off on flashing-green solid-green dot-off dot-on root@dellemc-diag-os:~# get Output root@dellemc-diag-os:~# ledtool --get Fan Led: off System Led: flashing-green Beacon Led: off Power Led: solid-green Stacking Led: off Stack-valled: Value 0x38 40 Dell DIAG-OS tools

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81

(or)
ledtool -s -Y
Test using config file:=
ledtool --test [--config=<config_file>]
(or)
ledtool -t [-f <config_file>]
Test LED manually
ledtool --test --manual
(or)
ledtool -t -m
Set led pre and post seetings :=
ledtool --set --led=<led> --mode=<mode> [normal]
(or)
ledtool -s -D <led> -M <mode>
Syntax: ledtool <option>
-h, --h
Show the help text
-l, --list
List the LEDs
-g, --get
Get operation
-s, --set
Set operation
-t, --test
Test using the pre-programmed configuration or use supplied config
-D, --led=
LED
-I, --iteration=
Iteration command execution
-S, --instance=,
Instance
-T, --state=,
State of the LED
-V, --val=,
Value to be set
-f, --config=,
To specify the location of the config file e.g. /etc/dn/diag/
<file_name>
-U, --cpu_ctrl,
Set CPU control
-Y, --fpga_ctrl,
Set FPGA control
-M, --mode,
Set CPLD Mode
-m, --manual,
Manual LED test
Output
list output
root@dellemc-diag-os:~# ledtool --list
Fan : options
off solid-amber solid-green flashing-amber
System : options
flashing-green solid-green solid-amber flashing-amber
Beacon : options
off flashing-blue
Power : options
off solid-amber solid-green flashing-amber
Stacking : options
solid-green off
Stack-val : options
0-F
7-digit : options
off on flashing-green solid-green dot-off dot-on
root@dellemc-diag-os:~#
get Output
root@dellemc-diag-os:~# ledtool --get
Fan Led: off
System Led: flashing-green
Beacon Led: off
Power Led: solid-green
Stacking Led: off
Stack-valled: Value 0x38